Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1999 Dec;82(6):1644-7.

Pharmacokinetics of recombinant factor VIII (recombinate) using one-stage clotting and chromogenic factor VIII assay

Affiliations
  • PMID: 10613649
Clinical Trial

Pharmacokinetics of recombinant factor VIII (recombinate) using one-stage clotting and chromogenic factor VIII assay

C A Lee et al. Thromb Haemost. 1999 Dec.

Abstract

In a study designed to demonstrate the safety and pharmacokinetics of a recombinant factor VIII (Recombinate) manufactured in Andover, MA and Thousand Oaks, CA, two different methods of factor VIII assay (one-stage clotting and Chromogenic substrate) were compared in vivo. The study was performed in four centres in the UK: London, Oxford, Cardiff and Manchester. Two pharmacokinetic studies, at least one week apart, were performed in 30 patients with severe haemophilia A (VIII:C < 2 IU/dl). A dose of 50 IU/kg was administered with sampling pre-infusion, and +0.25, 0.5, 1, 3, 6, 9, 12 and 24 h post-infusion. The aggregate 60 pharmacokinetic study showed a half-life of 12.7 and 13.0 h (p = 0.28) and recovery of 127 and 161 IU/dl (p = 0.0001) using one-stage clotting or chromogenic substrate respectively. In a supplementary experiment, 20 post-infusion samples were re-assayed by 1-stage and chromogenic assay using two plasma (20th British plasma standard and an "in-house" pooled normal plasma) and two concentrate standards, derived from the same type, but different batch of infused concentrate (Recombinate) and pre-diluted in either individual pre-infusion sample or in pooled commercial haemophilic plasma. The use of the Recombinate concentrate standard overcame the significant difference in FVIII levels between 1-stage and chromogenic assay methods when a plasma standard was used (p <0.0001). It is concluded that where potency dosing designation is carried out by an assay system different to that used in the clinical situation, the use of the recombinant concentrate as a standard in post-infusion plasma samples is likely to give more reliable and reproducible results.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources