Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999;28(2):127-41.
doi: 10.1068/p2778.

Disparity minimisation, cyclovergence, and the validity of nonius lines as a technique for measuring torsional alignment

Affiliations

Disparity minimisation, cyclovergence, and the validity of nonius lines as a technique for measuring torsional alignment

B J Rogers et al. Perception. 1999.

Abstract

Frisby et al (1993 Perception 22 Supplement, 115) proposed that the visual system might make cyclovergent eye movements in order to minimise the overall pattern of both vertical and horizontal disparities when an observer views an inclined stereoscopic surface. Their measurements of cyclovergence, which used vertically oriented nonius lines, were found to be consistent with that proposal. In our experiment 1, we measured torsional eye movements objectively, using scleral coils, and found no evidence of a cyclovergent response to either a real inclined surface or to a simulated inclined surface in which the two stereoscopic images were related by a horizontal shear transformation. These results are inconsistent with the disparity minimisation hypothesis. In order to account for the discrepant findings of the two studies, we propose that vertically oriented nonius lines may not be a valid method for assessing cyclovergence because the lines can be seen as lying 'within' the inclined surface. In experiment 2, we tested the predictions of the cyclovergence hypothesis of Frisby et al against our own 'within surface' explanation, using both horizontally and vertically oriented nonius lines and dichoptic images related by either a horizontal or a vertical shear. If cyclovergence were the cause of the misalignment, both horizontal and vertical nonius lines should appear misaligned to the same extent. This was not found to be the case. We conclude that vertical nonius lines may not be a valid technique for measuring cyclovergence when the lines are seen against a background of an inclined surface.

PubMed Disclaimer

Publication types

LinkOut - more resources