Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Nov-Dec;22(9):565-9.
doi: 10.1016/s0161-4754(99)70015-1.

Interexaminer reliability of activator methods' relative leg-length evaluation in the prone extended position

Affiliations

Interexaminer reliability of activator methods' relative leg-length evaluation in the prone extended position

H T Nguyen et al. J Manipulative Physiol Ther. 1999 Nov-Dec.

Abstract

Objective: To investigate the interexaminer reliability of the prone extended relative leg-length check as described by Activator Methods, Inc.

Subjects: Thirty-four subjects were selected from a pool of 52 consecutive patients visiting a private chiropractic office.

Methods: Exclusion criteria included congenital or acquired conditions known to affect lower extremity length and inability to lie prone for a 10-minute period. Two experienced chiropractors who specialize in Activator Methods and are "advanced-proficiency rated" by Activator Methods, Inc. assessed each patient in random order for leg length inequality. Findings were recorded as left short leg, equal leg length, or right short leg.

Results: The data for 34 subjects were organized in a 3 x 3 contingency table. Total agreement was 85%. A simple, unweighted kappa value yielded kappa = 0.66. A disproportionately greater number of right short leg findings than left short leg findings were observed by both examiners. In only 2 instances were equal leg lengths observed, and both were detected by the same examiner. Because examiners found only 2 of 34 subjects with equal leg lengths, several secondary analyses involving data reductions were conducted. The resulting kappa values were similar to the 3 x 3 analysis.

Conclusion: There was good reproducibility between 2 examiners by using the Activator Method to detect leg length inequality in the prone extended position. This study does not address the validity or clinical significance of the measurement method. Future studies should include larger numbers, a wider variety of subjects, and a diversity of examiners.

PubMed Disclaimer

Publication types

LinkOut - more resources