Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Jan;117(1):87-95.
doi: 10.1378/chest.117.1.87.

Pleural fluid pH as a predictor of pleurodesis failure: analysis of primary data

Affiliations
Clinical Trial

Pleural fluid pH as a predictor of pleurodesis failure: analysis of primary data

J E Heffner et al. Chest. 2000 Jan.

Abstract

Study objectives: To determine the predictive accuracy of pH for identifying patients with malignant pleural effusions who will fail pleurodesis.

Design: Analysis of published and unpublished individual patient-level data retrieved from a MEDLINE search and correspondence with primary investigators.

Study selection: Studies that reported pleural fluid pH values and outcomes of pleurodesis for patients with malignant pleural effusions.

Data collection and analysis: Primary investigators supplied data for 433 patients. Receiver operating characteristic analysis and logistic regression estimated the predictive accuracy, decision thresholds, and value of pleural fluid pH compared with other clinical factors. The primary investigations were graded for study design.

Results: Pleural fluid pH was the only independent predictor of pleurodesis failure (odds ratio, 4.46; 95% confidence interval [CI], 2.69 to 7.45; p < 0.0001) and had an area under the receiver operating characteristic curve (decision threshold, < or = 7.28) of 0.671 (95% CI, 0.624 to 0.715). The pH model fit the data well (p = 0.48) with the probability of pleurodesis failure increasing as pH decreased; specificity and negative predictive values for pleurodesis failure exceeded 90% and 80%, respectively, with a positive predictive value of 45.7% at pH values < or = 7.15. The primary studies had several important design limitations.

Conclusions: Using patient-level data, this study showed that pleural fluid pH has only modest predictive value for predicting symptomatic failure and should be used with caution, if at all, in selecting patients for pleurodesis. The limitations of the primary studies and low predictive accuracy should be considered when using pleural fluid pH for patient care.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources