Reliability of measurements of pulmonary artery pressure obtained with patients in the 60 degrees lateral position
- PMID: 10631390
Reliability of measurements of pulmonary artery pressure obtained with patients in the 60 degrees lateral position
Abstract
Background: Monitoring of pulmonary artery pressure is an essential component of the care of critically ill patients. The conditions under which reliable measurements can be obtained must be clarified.
Objectives: To determine (1) whether reliable measurements of pulmonary artery pressure can be obtained with patients in the right or left 60 degrees lateral position and (2) which characteristics of patients preclude obtaining reliable measurements.
Methods: One hundred five patients (65 cardiac surgery, 40 general medicine) with pulmonary artery catheters were enrolled in a prospective, stratified, quasi-experimental study. Subjects were repositioned from supine (head of bed elevated < 30 degrees with 1 pillow) to the left and right 60 degrees lateral positions. Systolic, diastolic, and mean pulmonary artery pressures and pulmonary capillary wedge pressure were measured before and 5, 10, and 20 minutes after lateral repositioning. The zero reference was the phlebostatic axis when patients were supine and the dependent midclavicular line at the level of the fourth intercostal space when patients were in the lateral positions.
Results: In most patients, measurements obtained with patients in the lateral position differed significantly from measurements obtained with patients supine. None of the variables examined were reliable predictors of which patients would have these differences. More than 11% of the patients had clinically significant differences in addition to the statistically significant differences.
Conclusion: Reliable measurements of pulmonary artery pressure and pulmonary capillary wedge pressure cannot be obtained with patients in the 60 degrees lateral position.
Comment in
-
Reliability of pulmonary artery pressure (PAP) measurements.Am J Crit Care. 2000 Jul;9(4):294-5. Am J Crit Care. 2000. PMID: 10888153 No abstract available.
Similar articles
-
Pulmonary artery pressure measurement in patients with elevated pressures: effect of backrest elevation and method of measurement.Am J Crit Care. 1992 Sep;1(2):61-9. Am J Crit Care. 1992. PMID: 1307892 Clinical Trial.
-
Comparisons of pulmonary artery pressure measurements in supine and 30 degree lateral positions.Can J Cardiovasc Nurs. 1995;6(3-4):4-8. Can J Cardiovasc Nurs. 1995. PMID: 8573278
-
Effect of position on selected hemodynamic parameters in postoperative cardiac surgery patients.Am J Crit Care. 1994 Jul;3(4):289-99. Am J Crit Care. 1994. PMID: 7920958 Clinical Trial.
-
Reproducibility of central venous pressures in supine and lateral positions: a pilot evaluation of the phlebostatic axis in critically ill patients.Heart Lung. 1994 Jul-Aug;23(4):285-99. Heart Lung. 1994. PMID: 7960854 Review.
-
Patient positioning and the accuracy of pulmonary artery pressure measurements (180f).Int J Nurs Stud. 1999 Dec;36(6):497-505. doi: 10.1016/s0020-7489(99)00033-4. Int J Nurs Stud. 1999. PMID: 10576120 Review.
Cited by
-
Lateral positioning for critically ill adult patients.Cochrane Database Syst Rev. 2016 May 12;2016(5):CD007205. doi: 10.1002/14651858.CD007205.pub2. Cochrane Database Syst Rev. 2016. PMID: 27169365 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical