A psychophysiological study of determinants for detection of deception
Abstract
Three studies were conducted to obtain available data on the determinants for detection of deception rates. (a) Psychophysiological measures were evaluated for effectiveness in detecting deception. A relevant-irrelevant method was used with two conditions; neutral stimulus and personal stimulus. Of the physiological variables, skin potential response, skin resistance response, finger pulse volume, and skin blood flow were significant indicators of deception. (b) Three experiments were conducted to study the psychophysiological effects of false and true feedback of skin potential response on the detection rates. It was concluded that the subjects receiving information that they were detectable were easier to detect than the subjects who believed that they were not detected and the subjects who received feedback of actual responses. (c) With the use of skin potential response channel, significant detection rates were obtained for all experiments under the condition that subjects verbally lied by means of "No" responses. On the other hand, the subjects who were motivated to deceive produced differentially augmented responses in the absence of any verbal response and also when the subjects told the truth to critical items and lied to irrelevant ones.
Similar articles
-
Separating deceptive and orienting components in a Concealed Information Test.Int J Psychophysiol. 2008 Nov;70(2):95-104. doi: 10.1016/j.ijpsycho.2008.07.002. Epub 2008 Jul 15. Int J Psychophysiol. 2008. PMID: 18674573
-
A Concealed Information Test with multimodal measurement.Int J Psychophysiol. 2010 Mar;75(3):258-67. doi: 10.1016/j.ijpsycho.2009.12.007. Epub 2009 Dec 21. Int J Psychophysiol. 2010. PMID: 20026133
-
Covert respiration measures for the detection of concealed information.Biol Psychol. 2008 Mar;77(3):284-91. doi: 10.1016/j.biopsycho.2007.11.001. Epub 2007 Nov 12. Biol Psychol. 2008. PMID: 18093718
-
Truth and deception: a reply to Lykken.Psychol Bull. 1979 Jan;86(1):54-9. Psychol Bull. 1979. PMID: 377355 Review. No abstract available.
-
Physiological measures and the detection of deception.Psychol Bull. 1977 Jul;84(4):782-99. Psychol Bull. 1977. PMID: 331381 Review. No abstract available.
Cited by
-
Estimating the accuracy of muscle response testing: two randomised-order blinded studies.BMC Complement Altern Med. 2016 Nov 30;16(1):492. doi: 10.1186/s12906-016-1416-2. BMC Complement Altern Med. 2016. PMID: 27903263 Free PMC article. Clinical Trial.