Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1999 Dec;14(6):267-71.
doi: 10.1007/s003840050226.

Detection of colorectal neoplasms by the highly sensitive hemoglobin-haptoglobin complex in feces

Affiliations
Clinical Trial

Detection of colorectal neoplasms by the highly sensitive hemoglobin-haptoglobin complex in feces

A Sieg et al. Int J Colorectal Dis. 1999 Dec.

Abstract

Screening for fecal occult blood by means of guaiac tests has an unsatisfactory sensitivity for the detection of colorectal neoplasms. The immunological determination of human hemoglobin in feces has a higher sensitivity and specificity, but hemoglobin is degraded during its transport through the gastrointestinal tract. We compared the hemoglobin test to a newly developed immuno-chemiluminometric (ILMA) assay for quantifying the hemoglobin-haptoglobin complex in feces which shows high stability against degradation. From each of 621 patients with gastrointestinal complaints before scheduled colonoscopy we collected two 1-ml samples from a single stool; there were no dietary restrictions. The sensitivity for detecting colorectal carcinomas proved 87% with hemoglobin. With the hemoglobin-haptoglobin complex it was 87% at a cutoff level of 1.5 microg/g feces, 83% at 2.0 microg/g feces, and 78% at 2.5 and 3.0 microg/g feces. The sensitivity for detecting large adenomatous polyps was 54% with hemoglobin, 76% with the hemoglobin-haptoglobin complex at a cutoff point of 1.5 microg/g feces, 73% with the hemoglobin-haptoglobin complex at 2.0 and 2.5 microg/g feces, and 65% with the hemoglobin-haptoglobin complex at 3.0 microg/g feces. The optimal cutoff point for the hemoglobin-haptoglobin complex was estimated to be 2.0 microg/g stool. The specificity for hemoglobin (99%) was significantly higher than that for the hemoglobin-haptoglobin complex at 2.0 microg/g feces (96%). Immunological determination of the hemoglobin-haptoglobin complex in feces has a comparable sensitivity as the fecal hemoglobin assay for colorectal carcinomas and a significantly higher sensitivity for adenomatous polyps but a significantly lower specificity. Its use for colorectal cancer prevention is currently being evaluated in a screening study.

PubMed Disclaimer

LinkOut - more resources