Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Jun;19(4):251-4.
doi: 10.1038/sj.jp.7200182.

Percutaneous central catheters and peripheral intravenous catheters have similar infection rates in very low birth weight infants

Affiliations

Percutaneous central catheters and peripheral intravenous catheters have similar infection rates in very low birth weight infants

J A Parellada et al. J Perinatol. 1999 Jun.

Abstract

Objective: We performed this study to determine if percutaneous central lines (PCLs) were associated with infection more often than peripherally placed intravenous catheters (PIVs).

Study design: We conducted a retrospective, cohort study of 53 infants with PCLs inserted from March 1993 to February 1995 for evidence of catheter-related bloodstream infection and 97 cohorts with PIVs who were matched to the infants with PCLs by admission date and birth weight. We considered an infant to have catheter-related bloodstream infection if bacteremia occurred while the PCL or PIV was in place with no other identifiable infection focus. Statistical analyses were performed by using either Student's t test or the Mann-Whitney U test where appropriate.

Results: There were eight infections per 1000 catheter days of PCL use and nine infections per 1000 catheter days of PIV use.

Conclusion: PCLs do not become infected more often than PIVs.