A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)
- PMID: 10698648
- DOI: 10.1006/jmre.1999.1956
A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)
Abstract
It has been previously shown that intrinsic metabolites can be imaged based on their water proton exchange rates using saturation transfer techniques. The goal of this study was to identify an appropriate chemical exchange site that could be developed for use as an exogenous chemical exchange dependent saturation transfer (CEST) contrast agent under physiological conditions. These agents would function by reducing the water proton signal through a chemical exchange site on the agent via saturation transfer. The ideal chemical exchange site would have a large chemical shift from water. This permits a high exchange rate without approaching the fast exchange limit at physiological pH (6.5-7.6) and temperature (37 degrees C), as well as minimizing problems associated with magnetic field susceptibility. Numerous candidate chemicals (amino acids, sugars, nucleotides, heterocyclic ring chemicals) were evaluated in this preliminary study. Of these, barbituric acid and 5, 6-dihydrouracil were more fully characterized with regard to pH, temperature, and concentration CEST effects. The best chemical exchange site found was the 5.33-ppm indole ring -NH site of 5-hydroxytryptophan. These data demonstrate that a CEST-based exogenous contrast agent for MRI is feasible.
Similar articles
-
Pushing the sensitivity envelope of lanthanide-based magnetic resonance imaging (MRI) contrast agents for molecular imaging applications.Acc Chem Res. 2009 Jul 21;42(7):822-31. doi: 10.1021/ar800192p. Acc Chem Res. 2009. PMID: 19534516 Review.
-
Osmotically shrunken LIPOCEST agents: an innovative class of magnetic resonance imaging contrast media based on chemical exchange saturation transfer.Chemistry. 2009;15(6):1440-8. doi: 10.1002/chem.200801766. Chemistry. 2009. PMID: 19115311
-
Improvement in the contrast of CEST MRI via intermolecular double quantum coherences.Phys Med Biol. 2008 Jul 21;53(14):N287-96. doi: 10.1088/0031-9155/53/14/N03. Epub 2008 Jun 23. Phys Med Biol. 2008. PMID: 18574314
-
A paramagnetic CEST agent for imaging glucose by MRI.J Am Chem Soc. 2003 Dec 17;125(50):15288-9. doi: 10.1021/ja038345f. J Am Chem Soc. 2003. PMID: 14664562
-
A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.Contrast Media Mol Imaging. 2015 May-Jun;10(3):163-178. doi: 10.1002/cmmi.1628. Epub 2015 Jan 12. Contrast Media Mol Imaging. 2015. PMID: 25641791 Free PMC article. Review.
Cited by
-
Ultrafast Z-spectroscopic imaging in vivo at 3T using through-slice spectral encoding (TS-UFZ).Magn Reson Med. 2023 Apr;89(4):1429-1440. doi: 10.1002/mrm.29532. Epub 2022 Nov 13. Magn Reson Med. 2023. PMID: 36373181 Free PMC article.
-
Chemical exchange saturation transfer of the cervical spinal cord at 7 T.NMR Biomed. 2016 Sep;29(9):1249-57. doi: 10.1002/nbm.3581. Epub 2016 Jul 26. NMR Biomed. 2016. PMID: 27459342 Free PMC article.
-
Quantitative chemical exchange saturation transfer MRI of intervertebral disc in a porcine model.Magn Reson Med. 2016 Dec;76(6):1677-1683. doi: 10.1002/mrm.26457. Epub 2016 Sep 26. Magn Reson Med. 2016. PMID: 27670140 Free PMC article.
-
Imaging in vivo extracellular pH with a single paramagnetic chemical exchange saturation transfer magnetic resonance imaging contrast agent.Mol Imaging. 2012 Feb;11(1):47-57. Mol Imaging. 2012. PMID: 22418027 Free PMC article.
-
MRI biosensor for protein kinase A encoded by a single synthetic gene.Magn Reson Med. 2012 Dec;68(6):1919-23. doi: 10.1002/mrm.24483. Epub 2012 Sep 28. Magn Reson Med. 2012. PMID: 23023588 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical