Quantification and rapid metabolite identification in drug discovery using API time-of-flight LC/MS
- PMID: 10701265
- DOI: 10.1021/ac9911701
Quantification and rapid metabolite identification in drug discovery using API time-of-flight LC/MS
Abstract
Liquid chromatography/mass spectrometry (LC/MS), utilizing a time-of-flight (TOF) mass analyzer, has been evaluated and applied to problems in bioanalysis for pharmacokinetics and drug metabolism. The data obtained by TOF MS differ from those obtained using quadrupole mass spectrometer instruments in that full-scan spectra can be routinely collected with greater sensitivity and speed. Both quantitative and qualitative information, including compound concentration in rat plasma and full-scan atmospheric pressure ionization mass spectra, are concurrently obtained. This approach has been used to characterize the disposition of several drug compounds that have been simultaneously dosed to rats in a cassette format. Quantitation limits in the 5-25 ng/mL range (approximately 20 nM) were obtained from nominal mass chromatograms (0.5 Da resolution). A reference lock mass was used to provide accurate mass measurement to reach third decimal place accuracy in the monoisotopic molecular weight. An improvement in quantitation limits was demonstrated after using accurate mass determinations. Several possible preliminary drug metabolites were confirmed or refuted, based on accurate mass. The trend of metabolite formation and clearance was qualitatively evaluated.
Similar articles
-
High-throughput liquid chromatography/mass spectrometry method for the quantitation of small molecules using accurate mass technologies in supporting discovery drug screening.Rapid Commun Mass Spectrom. 2013 Feb 15;27(3):401-8. doi: 10.1002/rcm.6461. Rapid Commun Mass Spectrom. 2013. PMID: 23280971
-
Metabolite characterization in drug discovery utilizing robotic liquid-handling, quadruple time-of-flight mass spectrometry and in-silico prediction.Curr Drug Metab. 2003 Aug;4(4):259-71. doi: 10.2174/1389200033489406. Curr Drug Metab. 2003. PMID: 12871044
-
Recent advances in metabolite identification and quantitative bioanalysis by LC-Q-TOF MS.Bioanalysis. 2012 May;4(8):937-59. doi: 10.4155/bio.12.43. Bioanalysis. 2012. PMID: 22533568 Review.
-
An introduction to hybrid ion trap/time-of-flight mass spectrometry coupled with liquid chromatography applied to drug metabolism studies.J Mass Spectrom. 2012 Dec;47(12):1627-42. doi: 10.1002/jms.3126. J Mass Spectrom. 2012. PMID: 23280752 Review.
-
Critical practical aspects in the application of liquid chromatography-mass spectrometric studies for the characterization of impurities and degradation products.J Pharm Biomed Anal. 2014 Jan;87:191-217. doi: 10.1016/j.jpba.2013.04.027. Epub 2013 Apr 28. J Pharm Biomed Anal. 2014. PMID: 23706957 Review.
Cited by
-
Mass spectrometry innovations in drug discovery and development.Pharm Res. 2001 Feb;18(2):131-45. doi: 10.1023/a:1011049231231. Pharm Res. 2001. PMID: 11405282 Review.
-
Rapid LC-MS drug metabolite profiling using microsomal enzyme bioreactors in a parallel processing format.Anal Chem. 2009 Dec 15;81(24):9921-9. doi: 10.1021/ac9015853. Anal Chem. 2009. PMID: 19904994 Free PMC article.
-
Correction of accurate mass measurement for target compound verification by quadrupole time-of-flight mass spectrometry.J Am Soc Mass Spectrom. 2005 Mar;16(3):406-8. doi: 10.1016/j.jasms.2004.11.022. J Am Soc Mass Spectrom. 2005. PMID: 15734334
-
Mass Accuracy Check Using Common Background Peaks for Improving Metabolome Data Quality in Chemical Isotope Labeling LC-MS.J Am Soc Mass Spectrom. 2019 Sep;30(9):1733-1741. doi: 10.1007/s13361-019-02248-w. Epub 2019 May 28. J Am Soc Mass Spectrom. 2019. PMID: 31140076
-
Quantitative-qualitative data acquisition using a benchtop Orbitrap mass spectrometer.J Am Soc Mass Spectrom. 2009 Aug;20(8):1441-50. doi: 10.1016/j.jasms.2009.03.002. Epub 2009 Mar 6. J Am Soc Mass Spectrom. 2009. PMID: 19339197
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical