Intravascular catheter-associated infections
- PMID: 10706172
- DOI: 10.1007/s100960050001
Intravascular catheter-associated infections
Abstract
Serious infections associated with intravascular catheters are common. The available data suggests there are likely to be more than 500 000 cases of catheter-associated bloodstream infections occurring annually in Western Europe and the USA. These may be associated with as many as 100 000 deaths. The pathophysiology of this common condition is still not fully elucidated. With catheters that are in place for short periods (a few days), microbial migration down the outer surface of the device to the intravascular tip predominates. For catheters that are in place for longer periods, migration occurs more often via the internal lumen. After being in place for more than 8 days, nearly all central vein catheters will have microorganisms embedded in a biofilm within the catheter lumen. In some catheters, microorganisms will proliferate to sufficient numbers for systemic sepsis to result. The occurrence and rate of this proliferation is dependent on microbial virulence factors, host factors, and characteristics of the catheter. Diagnosis of intravascular device-associated sepsis remains problematic because the pathophysiology of the condition changes with time and because standard culture techniques rarely detect organisms embedded in biofilms. The semiquantitative roll method on blood agar remains in common use because of its simplicity. However, the method only samples the external surface of the catheter. For catheters that have been in place for extended periods of time, methods that better sample the internal lumen, such as sonication and quantitative broth methods, should be developed and used.
Similar articles
-
Laboratory diagnosis of intravascular catheter associated sepsis.Eur J Clin Microbiol Infect Dis. 1989 Sep;8(9):807-14. doi: 10.1007/BF02185853. Eur J Clin Microbiol Infect Dis. 1989. PMID: 2512155 Review.
-
Intravenous catheter-related infections.Adv Pediatr Infect Dis. 1995;10:337-68. Adv Pediatr Infect Dis. 1995. PMID: 7718211 Review.
-
In situ diagnosis of intravascular catheter-related bloodstream infection: a comparison of quantitative culture, differential time to positivity, and endoluminal brushing.Crit Care Med. 2005 Apr;33(4):787-91. doi: 10.1097/01.ccm.0000157968.98476.f3. Crit Care Med. 2005. PMID: 15818106 Clinical Trial.
-
[The microbiology laboratory in the diagnosis of bacteremia associated with catheters].Enferm Infecc Microbiol Clin. 2000 Feb;18(2):62-5. Enferm Infecc Microbiol Clin. 2000. PMID: 10721574 Spanish.
-
Intravascular catheter associated sepsis: a common problem. The Australian Study on Intravascular Catheter Associated Sepsis.Med J Aust. 1994 Sep 19;161(6):374-8. Med J Aust. 1994. PMID: 8090116 Review.
Cited by
-
Involvement of curli fimbriae in the biofilm formation of Enterobacter cloacae.J Microbiol. 2012 Feb;50(1):175-8. doi: 10.1007/s12275-012-2044-2. Epub 2012 Feb 27. J Microbiol. 2012. PMID: 22367955
-
In silico molecular modelling studies and antibiofilm efficacy of shikonin against Candida albicans: mechanistic insight.Arch Microbiol. 2023 Feb 17;205(3):93. doi: 10.1007/s00203-023-03426-x. Arch Microbiol. 2023. PMID: 36800037
-
Central venous catheter related infections: risk factors and the effect of glycopeptide antibiotics.Ann Clin Microbiol Antimicrob. 2003 Feb 27;2:3. doi: 10.1186/1476-0711-2-3. Ann Clin Microbiol Antimicrob. 2003. PMID: 12643811 Free PMC article.
-
Development and characterization of an in vivo central venous catheter Candida albicans biofilm model.Infect Immun. 2004 Oct;72(10):6023-31. doi: 10.1128/IAI.72.10.6023-6031.2004. Infect Immun. 2004. PMID: 15385506 Free PMC article.
-
Pathogenesis and treatment of oral candidosis.J Oral Microbiol. 2011 Jan 28;3. doi: 10.3402/jom.v3i0.5771. J Oral Microbiol. 2011. PMID: 21547018 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources