Rapid discrimination between methicillin-sensitive and methicillin-resistant Staphylococcus aureus by intact cell mass spectrometry
- PMID: 10707951
- DOI: 10.1099/0022-1317-49-3-295
Rapid discrimination between methicillin-sensitive and methicillin-resistant Staphylococcus aureus by intact cell mass spectrometry
Abstract
Rapid, accurate discrimination between methicillin-sensitive Staphylococcus aureus (MSSA) and methicillin-resistant S. aureus (MRSA) strains is essential for appropriate therapeutic management and timely intervention for infection control. A rapid method involving intact cell mass spectrometry (ICMS) is presented that shows promise for identification, discrimination of MSSA from MRSA and typing. In ICMS, cells from a bacterial colony are emulsified in a chemical matrix, added to a sample slide, dried and analysed by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS). This technique examines the chemistry of the intact bacterial cell surface, yielding spectra consisting of a series of peaks from 500 to 10000, which represent the mass:charge (m:z) ratios. Each peak corresponds to a molecular fragment released from the cell surface during laser desorption. Specimens can be prepared in a few seconds from plate cultures and a spectrum can be obtained within 2 min. ICMS spectra for 20 staphylococcal isolates showed characteristic peaks, some of which were conserved at species level, some at strain level and some were characteristic of the methicillin susceptibility status of the strain. ICMS may have potential for MRSA identification and typing, and may improve infection control measures.
Similar articles
-
Culture conditions and sample preparation methods affect spectrum quality and reproducibility during profiling of Staphylococcus aureus with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.Lett Appl Microbiol. 2013 Aug;57(2):144-50. doi: 10.1111/lam.12092. Epub 2013 May 20. Lett Appl Microbiol. 2013. PMID: 23617594
-
Rapid Discrimination between Methicillin-Sensitive and Methicillin-Resistant Staphylococcus aureus Using MALDI-TOF Mass Spectrometry.Biocontrol Sci. 2017;22(3):163-169. doi: 10.4265/bio.22.163. Biocontrol Sci. 2017. PMID: 28954959
-
Characterization of Staphylococcus aureus isolated from clinical specimens by matrix assisted laser desorption/ionization time-of-flight mass spectrometry.Biomed Environ Sci. 2013 Jun;26(6):430-6. doi: 10.3967/0895-3988.2013.06.003. Biomed Environ Sci. 2013. PMID: 23816576
-
Identification and discrimination of Staphylococcus aureus strains using matrix-assisted laser desorption/ionization-time of flight mass spectrometry.Proteomics. 2002 Jun;2(6):747-53. doi: 10.1002/1615-9861(200206)2:6<747::AID-PROT747>3.0.CO;2-V. Proteomics. 2002. PMID: 12112858
-
Intact cell mass spectrometry (ICMS) used to type methicillin-resistant Staphylococcus aureus: media effects and inter-laboratory reproducibility.J Microbiol Methods. 2002 Feb;48(2-3):117-26. doi: 10.1016/s0167-7012(01)00316-5. J Microbiol Methods. 2002. PMID: 11777562
Cited by
-
MALDI-TOF Mass Spectroscopy Applications in Clinical Microbiology.Adv Pharmacol Pharm Sci. 2021 May 7;2021:9928238. doi: 10.1155/2021/9928238. eCollection 2021. Adv Pharmacol Pharm Sci. 2021. PMID: 34041492 Free PMC article. Review.
-
Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Use with Positive Blood Cultures: Methodology, Performance, and Optimization.J Clin Microbiol. 2017 Dec;55(12):3328-3338. doi: 10.1128/JCM.00868-17. Epub 2017 Aug 30. J Clin Microbiol. 2017. PMID: 28855303 Free PMC article. Review.
-
Rapid and robust MALDI-TOF MS techniques for microbial identification: a brief overview of their diverse applications.J Microbiol. 2018 Apr;56(4):209-216. doi: 10.1007/s12275-018-7457-0. Epub 2018 Feb 28. J Microbiol. 2018. PMID: 29492868 Review.
-
Serotype-identifying ions in Listeria monocytogenes using matrix-associated laser desorption ionization-time of flight mass spectrometry.Heliyon. 2022 Nov 19;8(12):e11769. doi: 10.1016/j.heliyon.2022.e11769. eCollection 2022 Dec. Heliyon. 2022. PMID: 36466572 Free PMC article.
-
False-negative test results in the Slidex Staph Plus (bioMérieux) agglutination test are mainly caused by spa-type t001 and t001-related strains.Eur J Clin Microbiol Infect Dis. 2011 Feb;30(2):201-8. doi: 10.1007/s10096-010-1070-4. Epub 2010 Oct 9. Eur J Clin Microbiol Infect Dis. 2011. PMID: 20936317
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical