Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2000 Mar;117(3):773-8.
doi: 10.1378/chest.117.3.773.

Comparative efficacy of positron emission tomography with fluorodeoxyglucose in evaluation of small (<1 cm), intermediate (1 to 3 cm), and large (>3 cm) lymph node lesions

Affiliations
Comparative Study

Comparative efficacy of positron emission tomography with fluorodeoxyglucose in evaluation of small (<1 cm), intermediate (1 to 3 cm), and large (>3 cm) lymph node lesions

N C Gupta et al. Chest. 2000 Mar.

Abstract

Purpose: Our objective was to determine if positron emission tomography (PET) with fluorodeoxyglucose (FDG; PET-FDG) imaging is equally efficacious in detection of metastases in small and large mediastinal lymph nodes as compared to CT scanning.

Materials and methods: PET-FDG imaging, CT scanning, and histology results of sampled mediastinal lymph nodes were compared in 54 patients of total 118 patients studied. Efficacy of PET and CT was determined and compared in small (< 1 cm), intermediate (1 to 3 cm), and large (> 3 cm) mediastinal lesions.

Results: PET was accurate in 94% of patients in characterizing "N" disease as compared to 61% with CT. Overall, sensitivity, specificity, and accuracy of PET for staging mediastinal lymph nodes (n = 168 in 54 patients) was 96, 93, and 94%, as compared to 68, 65, and 66% with CT. Positive and negative predictive value of PET in detecting mediastinal adenopathy was 86% and 98%, as compared to 47% and 82% with CT, respectively. PET was also highly reliable and accurate for detecting lymph nodes < 1 cm, 1 to 3 cm, and > 3 cm in size with superior efficacy than CT. Sensitivity, specificity, and accuracy of PET for detecting malignancy in lymph node lesions < 1 cm in size was 97, 82, and 95%, respectively.

Conclusion: PET-FDG imaging is equally reliable and accurate for detecting disease in small and large lymph node lesions in patients with suspected or proven lung cancer with better efficacy than CT.

PubMed Disclaimer

Publication types

MeSH terms