. 2000 Apr;55(4):314-7.
doi: 10.1136/thorax.55.4.314.

Analysis of ciliary beat pattern and beat frequency using digital high speed imaging: comparison with the photomultiplier and photodiode methods

Affiliations

Analysis of ciliary beat pattern and beat frequency using digital high speed imaging: comparison with the photomultiplier and photodiode methods

M A Chilvers et al. Thorax. 2000 Apr.

Abstract

Background: The aim of this study was to determine the relationship of the power and recovery stroke of respiratory cilia using digital high speed video imaging. Beat frequency measurements made using digital high speed video were also compared with those obtained using the photomultiplier and modified photodiode techniques.

Method: Ciliated epithelium was obtained by brushing the inferior nasal turbinate of 20 healthy subjects. Ciliated edges were observed by microscopy and the deviation of cilia during their recovery stroke relative to the path travelled during their power stroke was measured. Beat frequency measurements made by digital high speed video analysis were compared with those obtained using the photomultiplier and modified photodiode.

Results: Cilia were found to beat with a forward power stroke and a backward recovery stroke within the same plane. The mean angular deviation of the cilia during the recovery stroke from the plane of the forward power stroke was only 3.6 degrees (95% CI 3.1 to 4.1). There was a significant difference in beat frequency measurement between the digital high speed video (13.2 Hz (95% CI 11.8 to 14.6)) and both photomultiplier (12.0 Hz (95% CI 10.8 to 13.1), p = 0.01) and photodiode (11.2 Hz (95% CI 9.9 to 12.5), p<0.001) techniques. The Bland-Altman limits of agreement for the digital high speed video were -2.75 to 5.15 Hz with the photomultiplier and -2.30 to 6.06 Hz with the photodiode.

Conclusion: Respiratory cilia beat forwards and backwards within the same plane without a classical sideways recovery sweep. Digital high speed video imaging allows both ciliary beat frequency and beat pattern to be evaluated.

PubMed Disclaimer

References

    1. Ann Otol Rhinol Laryngol. 1991 May;100(5 Pt 1):378-84 - PubMed
    1. Pediatr Pulmonol. 1988;5(1):36-50 - PubMed
    1. Chest. 1992 Jul;102(1):284-7 - PubMed
    1. Acta Otolaryngol. 1993 Sep;113(5):655-9 - PubMed
    1. Respir Med. 1994 Feb;88(2):89-101 - PubMed

Publication types