Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Sep;63(Pt 5):383-91.
doi: 10.1046/j.1469-1809.1999.6350383.x.

Superiority of denaturing high performance liquid chromatography over single-stranded conformation and conformation-sensitive gel electrophoresis for mutation detection in TSC2

Affiliations
Comparative Study

Superiority of denaturing high performance liquid chromatography over single-stranded conformation and conformation-sensitive gel electrophoresis for mutation detection in TSC2

Y S Choy et al. Ann Hum Genet. 1999 Sep.

Abstract

We evaluated denaturing high pressure liquid chromatography (DHPLC) as a scanning method for mutation detection in TSC2, and compared it to conformation-sensitive gel electrophoresis (CSGE) and single-stranded conformation polymorphism analysis (SSCP). The first 20 exons of TSC2 were amplified from 84 TSC patients and screened initially by CSGE and then by DHPLC. Optimization of DHPLC analysis of each exon was carried out by design of primers with minimum variation in the melting temperature of the amplicon, and titration of both elution gradient and temperature. CSGE analysis identified 40 shifts (21 unique) in the 84 patients and 20 exons. All of these variants were detected by DHPLC, and an additional 27 changes (14 unique) were identified. Overall 15 of 28 (54%) unique single base substitutions were detected by CSGE; all were detected by DHPLC. 25 definite or probable mutations were found in these 84 patients (30%) in exons 1-20 of TSC2. In a subsequent blinded analysis of 15 samples with 18 distinct TSC2 sequence variants originally detected by SSCP in another centre, all variants were detected by DHPLC except one where the variation occurred within the primer. Ten other (7 unique) sequence variants were detected in these samples which had not been detected by SSCP. Overall, 11 of 16 (69%) unique single base substitutions were detected by SSCP; all were detected by DHPLC. We conclude that DHPLC is superior to both CSGE and SSCP for detection of DNA sequence variation in TSC2, particularly for single base substitution mutations.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources