Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2000 Mar;14(3):246-9.
doi: 10.1007/s004640000028.

Vascular injuries within the hepatoduodenal ligament: recognition by laparoscopic color Doppler ultrasound

Affiliations
Comparative Study

Vascular injuries within the hepatoduodenal ligament: recognition by laparoscopic color Doppler ultrasound

M Birth et al. Surg Endosc. 2000 Mar.

Abstract

Background: Lesions of vascular structures are rare but serious complications of laparoscopic cholecystectomy. The purpose of this blind randomized animal study was to investigate the possibility of detecting different vascular lesions within the hepatoduodenal ligament using laparoscopic color Doppler ultrasound (LCDU).

Methods: Twenty-four lesions of the hepatic artery and portal vein were created laparoscopically in six farmer pigs using titanium clips. The following injuries were studied: (a) partial occlusion of the hepatic artery (eight cases), (b) complete occlusion of the hepatic artery (eight cases), (c) partial occlusion of the portal vein (eight cases). There were also eight cases without lesions of the vascular vessels. The order in which the injuries were created was randomly assigned. The study was performed in a blind fashion. Recognition of the injuries was attempted with LCDU.

Results: All injuries were recognized correctly by LCDU. There were no false positive results. The clips were reliably located. Using color Doppler imaging, partial occlusions of the hepatic artery and portal vein were visualized by changes of the blood flow from laminar to turbulent behind the clip. Complete occlusion of the hepatic artery was recognized as a complete cessation of the colored blood flow.

Conclusion: LCDU is a very efficient tool for visualizing vascular structures and evaluating the bloodstream. Partial or complete vascular occlusion by clips that may occur as a result of difficult dissection during laparoscopic cholecystectomy can be visualized reliably using this technique.