Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2000 Jan-Mar;10(1):4-10.
doi: 10.1177/112067210001000102.

Distance alternate-letter suppression test for objective assessment of sensorial status in intermittent exotropia

Affiliations

Distance alternate-letter suppression test for objective assessment of sensorial status in intermittent exotropia

C Yildirim et al. Eur J Ophthalmol. 2000 Jan-Mar.

Abstract

Purpose: To investigate the value of distance alternate-letter suppression testing in the objective assessment of fusional control of intermittent exotropia.

Methods: A total of 71 consecutive patients with intermittent exotropia (study group) and 112 normal subjects (control group) underwent a series of measurements including distance alternate-letter suppression testing, Worth 4 Dot test at distance and near, and distance and near stereo acuity tests to see whether sensorial behavior differed in the study and control groups. The distance alternate-letter suppression test and distance stereo acuity tests were performed using the Mentor B-VAT II-SG Video Acuity Tester and Binocular Vision Testing System. The TNO test was used to measure near stereo acuity.

Results: Seventeen patients with intermittent exotropia (24%) presented suppression with the distance alternate-letter suppression test, but none of the normal subjects (p<0.001, chi2 test). Only, three patients (4%) showed suppression on the Worth 4 Dot test at distance, and all had fusion on the Worth 4 Dot test near. Patients with intermittent exotropia had significantly diminished distance stereo acuity compared to normal subjects (p<0.001). Normal subjects and patients had good near stereo acuity (p>0.05). Patients with intermittent exotropia who had fusion with the distance alternate-letter suppression test had significantly better distance stereo acuity than patients who had suppression (p<0.001).

Conclusions: Distance alternate-letter suppression testing and distance stereo acuity tests may be useful as objective measures for assessing sensory loss in patients with intermittent exotropia.

PubMed Disclaimer

LinkOut - more resources