Helical CT for the evaluation of suspected acute pulmonary embolism: diagnostic pitfalls
- PMID: 10752891
- DOI: 10.1097/00004728-200003000-00016
Helical CT for the evaluation of suspected acute pulmonary embolism: diagnostic pitfalls
Abstract
Helical CT is being increasingly utilized for the evaluation of suspected pulmonary embolism (PE). Proper scan interpretation depends on the awareness of several diagnostic pitfalls that may simulate PE, including normal bronchovascular structures such as pulmonary veins, bronchi, and lymph nodes, technical considerations such as improper bolus timing and streak artifacts, and patient-related factors such as motion artifacts, pulmonary arterial catheters, and vascular shunts. An understanding of these pitfalls facilitates accurate diagnosis.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical