Feasibility of partial A2 and A4 pulley excision: residual pulley strength
- PMID: 10763733
- DOI: 10.1054/jhsb.1999.0332
Feasibility of partial A2 and A4 pulley excision: residual pulley strength
Abstract
We investigated residual digital flexor pulley strengths after 75% excision of the A2 and A4 pulleys. For direct pull-off tests, A2 and A4 pulleys from cadaveric fingers were tested by pulling on a loop of flexor digitorum profundus tendon through the pulley. For functional loading tests, fingers were positioned with the metacarpophalangeal joint flexed to 90 degrees for A2 testing, and with the proximal interphalangeal joint in 90 degrees flexion for A4 testing (with all other joints in full extension). Excision of 75% of A2 and A4 pulleys reduced pulley strengths determined by both testing methods. For the functional loading tests, which are more clinically relevant, mean tendon forces at failure after partial excision of A2 and A4 pulleys were 224 and 131 N respectively, which is sufficient to withstand flexor tendon forces expected during activities of daily living.
Similar articles
-
Feasibility of partial A2 and A4 pulley excision: effect on finger flexor tendon biomechanics.J Hand Surg Am. 1999 Mar;24(2):310-4. doi: 10.1053/jhsu.1999.0310. J Hand Surg Am. 1999. PMID: 10194015
-
Effect of A3 pulley and adjacent sheath integrity on tendon excursion and bowstringing.J Hand Surg Am. 2001 Sep;26(5):855-61. doi: 10.1053/jhsu.2001.27768. J Hand Surg Am. 2001. PMID: 11561238
-
Strength of tendon repair decreases in the presence of an intact A2 pulley: biomechanical study in a chicken model.J Hand Surg Am. 2009 Dec;34(10):1763-70. doi: 10.1016/j.jhsa.2009.08.012. J Hand Surg Am. 2009. PMID: 19969186
-
Flexor pulley system: anatomy, injury, and management.J Hand Surg Am. 2014 Dec;39(12):2525-32; quiz 2533. doi: 10.1016/j.jhsa.2014.06.005. Epub 2014 Nov 21. J Hand Surg Am. 2014. PMID: 25459958 Review.
-
[Flexor tendon pulley system: anatomy, pathology, treatment].Chir Main. 2003 Feb;22(1):1-12. doi: 10.1016/s1297-3203(02)00010-0. Chir Main. 2003. PMID: 12723303 Review. French.
Cited by
-
Importance of proximal A2 and A4 pulleys to maintaining kinematics in the hand: a biomechanical study.Hand (N Y). 2014 Mar;9(1):105-11. doi: 10.1007/s11552-013-9547-0. Hand (N Y). 2014. PMID: 24570646 Free PMC article.
-
Feasibility of Homodigital Flexor Digitorum Superficialis transposition, a new technique for A2-C1 pulleys reconstruction: A kinematic cadaver study.J Orthop. 2020 Sep 8;21:483-486. doi: 10.1016/j.jor.2020.09.001. eCollection 2020 Sep-Oct. J Orthop. 2020. PMID: 32982105 Free PMC article.
-
High-resolution ultrasound tendon-to-bone distances in partial and complete finger flexor A2 pulley ruptures simulated in human cadaver dissection: toward understanding imaging of partial pulley ruptures.Front Bioeng Biotechnol. 2023 Jun 7;11:1123857. doi: 10.3389/fbioe.2023.1123857. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 37351474 Free PMC article.
-
Biomechanical Evaluation of a Novel V-Shaped A2 Pulley Reconstruction Technique Using a Free Palmaris Longus Tendon Graft Tenodesis.J Clin Med. 2025 Feb 8;14(4):1092. doi: 10.3390/jcm14041092. J Clin Med. 2025. PMID: 40004623 Free PMC article.
-
Identifying Palmar Skin Surface Landmark for Locating A2 Pulley during Cadaveric Dissection of the Hand.Plast Reconstr Surg Glob Open. 2023 Jul 25;11(7):e5138. doi: 10.1097/GOX.0000000000005138. eCollection 2023 Jul. Plast Reconstr Surg Glob Open. 2023. PMID: 37496981 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources