Multisorbent tubes for collecting volatile organic compounds in spacecraft air
- PMID: 10772617
Multisorbent tubes for collecting volatile organic compounds in spacecraft air
Abstract
The sampling capability of Tenax-TA tubes, used in the National Aeronautics and Space Administration's solid sorbent air sampler to trap and concentrate contaminants from air aboard spacecraft, was improved by incorporating two sorbents within the tubes. Existing tubes containing only Tenax-TA allowed highly volatile compounds to "break through" during collection of a 1.5 L air sample. First the carbon molecular sieve-type sorbents Carboxen 569 and Carbosieve S-III were tested for their ability to quantitatively trap the highly volatile compounds. Breakthrough volumes were determined with the direct method, whereby low ppm levels of methanol or Freon 12 in nitrogen were flowed through the sorbent tubes at 30 mL/min, and breakthrough was detected by gas chromatography. Breakthrough volumes for methanol were about 9 L/g on Carboxen 569 and 11 L/g on Carbosieve S-III; breakthrough volumes for Freon 12 were about 7 L/g on Carboxen 569 and > 26 L/g on Carbosieve S-III. Next, dual-bed tubes containing either Tenax-TA/Carbosieve S-III, Tenax-TA/Carboxen 569, or Carbotrap/Carboxen 569 to a 10-component gas mixture were exposed, in dry and in humidified air (50% relative humidity), and percentage recoveries of each compound were determined. The Tenax-TA/Carboxen 569 combination gave the best overall recoveries (75-114% for the 10 compounds). Acetaldehyde had the lowest recovery (75%) of the 10 compounds, but this value was still an improvement over either the other two sorbent combinations or the original single-sorbent tubes.
Similar articles
-
Comparative study of the adsorption performance of a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and a Tenax TA adsorbent tube for the analysis of volatile organic compounds (VOCs).Talanta. 2010 May 15;81(3):916-24. doi: 10.1016/j.talanta.2010.01.037. Epub 2010 Jan 25. Talanta. 2010. PMID: 20298873
-
Determination of volatile organic compounds in workplace air by multisorbent adsorption/thermal desorption-GC/MS.Chemosphere. 2004 Jul;56(1):71-80. doi: 10.1016/j.chemosphere.2004.02.003. Chemosphere. 2004. PMID: 15109881
-
Measurement of breakthrough volumes of volatile chemical warfare agents on a poly(2,6-diphenylphenylene oxide)-based adsorbent and application to thermal desorption-gas chromatography/mass spectrometric analysis.J Chromatogr A. 2015 Sep 4;1410:19-27. doi: 10.1016/j.chroma.2015.07.077. Epub 2015 Jul 22. J Chromatogr A. 2015. PMID: 26239699
-
Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.J Chromatogr A. 2010 Apr 16;1217(16):2674-84. doi: 10.1016/j.chroma.2009.12.042. Epub 2010 Jan 11. J Chromatogr A. 2010. PMID: 20106481 Review.
-
Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air. Part 2. Sorbent selection and other aspects of optimizing air monitoring methods.J Chromatogr A. 2010 Apr 16;1217(16):2685-94. doi: 10.1016/j.chroma.2010.01.015. Epub 2010 Jan 14. J Chromatogr A. 2010. PMID: 20106482 Review.
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Medical