Effect of finishing technique on the microleakage and surface texture of resin-modified glass ionomer restorative materials
- PMID: 10785304
- DOI: 10.1016/s0300-5712(99)00075-5
Effect of finishing technique on the microleakage and surface texture of resin-modified glass ionomer restorative materials
Abstract
Purpose: The purpose of this study was to evaluate the effects of wet and dry finishing/polishing procedures on the microleakage and surface texture of resin-modified glass ionomer (RMGI) restorative materials.
Materials and methods: Class V cavity preparations were made at the cemento-enamel junction (CEJ) on the buccal and lingual surface of 30 extracted human molars. The teeth were restored in three groups of 10 (20 preparations in each group) using Fuji II LC and Vitremer, both RMGIs, and Fuji II, a capsulated conventional glass ionomer cement (control). One restoration per tooth was finished/polished with copious applications of water and the other was finished/polished without water. All restorations were finished/polished using a sequence of four abrasive disks. Finishing/polishing was initiated according to manufacturers' instructions-immediately after light-curing Fuji II LC and Vitremer, and 15min after placement for Fuji II. The specimens were thermocycled and subjected to a silver nitrate leakage test. Each tooth was sectioned buccolingually and examined with an optical microscope at 40x to determine the extent of microleakage at enamel and dentin margins. The data were subjected to a non-parametric statistical analysis. To evaluate surface roughness after polishing, three disks each of Vitremer and Fuji II LC were fabricated in Teflon molds. One disk of each material was not finished/polished (control). The others were finished/polished using Sof-Lex abrasive disks. One specimen of each material was kept wet during all finishing/polishing procedures, while the other was kept dry. Atomic force microscopy was used to determine the average roughness (R(a)) of the specimens.
Results: For each material, microleakage at the enamel margin was very slight. Leakage of the conventional glass ionomer Fuji II was severe at dentin margins. Statistical analysis indicated that both Vitremer and Fuji II LC had significantly less leakage than Fuji II, and that Vitremer had significantly less leakage than Fuji II LC (p<0.05). Leakage at enamel margins was significantly less than at dentin margins. Differences related to wet and dry polishing were not statistically significant. Profilometry data indicated that polished specimens were rougher than those cured against a Mylar strip. Wet polishing created greater surface roughness than dry polishing.
Conclusions: RMGIs rather than conventional glass ionomers should be used in Class V cavity sites to allow immediate finishing and to reduce the incidence of microleakage. Dry finishing of RMGIs with abrasive disks is recommended because it produces a smoother surface and does not contribute to microleakage. However, wet finishing of conventional glass ionomers is still recommended to avoid desiccation.
Similar articles
-
Microleakage of Class V resin-modified glass ionomer and compomer restorations.J Prosthet Dent. 1999 May;81(5):610-5. doi: 10.1016/s0022-3913(99)70217-9. J Prosthet Dent. 1999. PMID: 10220667 Clinical Trial.
-
Effect of various surface protections on the margin microleakage of resin-modified glass ionomer cements.J Prosthet Dent. 2001 Sep;86(3):309-14. doi: 10.1067/mpr.2001.116133. J Prosthet Dent. 2001. PMID: 11552169
-
The influence of finishing time on the marginal seal of a resin-modified glass-ionomer and polyacid-modified resin composite.J Oral Rehabil. 1999 Jan;26(1):48-52. doi: 10.1046/j.1365-2842.1999.00323.x. J Oral Rehabil. 1999. PMID: 10080324
-
Review: finishing and polishing procedures of (resin-modified) glass ionomers and compomers in paediatric dentistry.Eur Arch Paediatr Dent. 2007 Mar;8(1):22-8. doi: 10.1007/BF03262566. Eur Arch Paediatr Dent. 2007. PMID: 17394887 Review.
-
Sealing Ability of Nano-ionomer in Primary Teeth: An ex vivo Study.Int J Clin Pediatr Dent. 2016 Jul-Sep;9(3):209-213. doi: 10.5005/jp-journals-10005-1365. Epub 2016 Sep 27. Int J Clin Pediatr Dent. 2016. PMID: 27843251 Free PMC article. Review.
Cited by
-
[Surface roughness, gloss and sequential polishing times of various chairside computer aided design/manufacturing restorative materials].Beijing Da Xue Xue Bao Yi Xue Ban. 2022 Jun 18;54(3):565-571. doi: 10.19723/j.issn.1671-167X.2022.03.025. Beijing Da Xue Xue Bao Yi Xue Ban. 2022. PMID: 35701137 Free PMC article. Chinese.
-
Evaluation of surface characteristics of dental composites using profilometry, scanning electron, atomic force microscopy and gloss-meter.J Mater Sci Mater Med. 2007 Jan;18(1):155-63. doi: 10.1007/s10856-006-0675-8. J Mater Sci Mater Med. 2007. PMID: 17200827
-
Evaluation of the Microleakage of Chlorhexidine-Modified Glass Ionomer Cement: An in vivo Study.Int J Clin Pediatr Dent. 2013 Jan;6(1):7-11. doi: 10.5005/jp-journals-10005-1177. Epub 2013 Apr 26. Int J Clin Pediatr Dent. 2013. PMID: 25206179 Free PMC article.
-
Effect of Staining and External Bleaching on the Color Stability and Surface Roughness of Universal-Shade Resin-Based Composite.Clin Cosmet Investig Dent. 2025 Jan 6;17:1-12. doi: 10.2147/CCIDE.S494320. eCollection 2025. Clin Cosmet Investig Dent. 2025. PMID: 39802459 Free PMC article.
-
Glass ionomer cements and their role in the restoration of non-carious cervical lesions.J Appl Oral Sci. 2009 Sep-Oct;17(5):364-9. doi: 10.1590/s1678-77572009000500003. J Appl Oral Sci. 2009. PMID: 19936509 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources