Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty
- PMID: 10793452
- DOI: 10.1111/j.1540-8159.2000.tb00845.x
Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty
Abstract
The procedure of lead removal has recently matured into a definable, teachable art with its own specific tools and techniques. It is now time to recognize and formalize the practice of lead removal according to the current methods of medicine and the health care industry. In addition, since at this time the only prospective scientific study of lead extraction is the PLEXES trial, we suggest that studies relating to the techniques of and indications for lead extraction be designed. Recommendations for a common set of definitions, for a framework of training and reviewing physicians in the art, for general methods of reimbursement, and for consistency among clinical trials have been made. Implementation of these recommendations will require additional effort and cooperation from practicing physicians, medical societies, hospital administrations, and industry.
Similar articles
-
Complications of permanent cardiac pacing in patients with persistent left superior vena cava.Cardiol J. 2014;21(2):128-37. doi: 10.5603/CJ.a2014.0006. Epub 2014 Feb 14. Cardiol J. 2014. PMID: 24526508
-
Extraction of transvenous pacing and ICD leads.Pacing Clin Electrophysiol. 2008 Jun;31(6):736-52. doi: 10.1111/j.1540-8159.2008.01079.x. Pacing Clin Electrophysiol. 2008. PMID: 18507548 Review.
-
Current concepts in extraction of transvenous pacing and ICD leads.Cardiol Clin. 2000 Feb;18(1):193-217. doi: 10.1016/s0733-8651(05)70134-x. Cardiol Clin. 2000. PMID: 10709692 Review.
-
Evolution in transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using a mechanical dilator sheath.Pacing Clin Electrophysiol. 2012 Jul;35(7):834-40. doi: 10.1111/j.1540-8159.2012.03385.x. Epub 2012 Apr 5. Pacing Clin Electrophysiol. 2012. PMID: 22486778 Clinical Trial.
-
Percutaneous extraction of transvenous defibrillator leads using the VascoExtor pacing lead removal system.J Interv Card Electrophysiol. 1999 Oct;3(3):247-51. doi: 10.1023/a:1009899708781. J Interv Card Electrophysiol. 1999. PMID: 10490481
Cited by
-
Safety and feasibility of coronary sinus left ventricular leads extraction: a preliminary report.J Interv Card Electrophysiol. 2005 Jun;13(1):35-8. doi: 10.1007/s10840-005-0910-0. J Interv Card Electrophysiol. 2005. PMID: 15976976
-
Octogenarian patients and laser-assisted lead extraction: Should we put a limit?PLoS One. 2023 Oct 20;18(10):e0284802. doi: 10.1371/journal.pone.0284802. eCollection 2023. PLoS One. 2023. PMID: 37862289 Free PMC article.
-
A single-centre experience of over one thousand lead extractions.Europace. 2009 May;11(5):612-7. doi: 10.1093/europace/eup054. Epub 2009 Mar 27. Europace. 2009. PMID: 19329797 Free PMC article.
-
Sonication of explanted cardiac implants improves microbial detection in cardiac device infections.J Clin Microbiol. 2013 Feb;51(2):496-502. doi: 10.1128/JCM.02230-12. Epub 2012 Nov 28. J Clin Microbiol. 2013. PMID: 23196364 Free PMC article.
-
Determinants of procedural outcome of chronically implanted pacemaker and defibrillator leads using the Excimer laser sheath.Heart. 2002 Feb;87(2):160-1. doi: 10.1136/heart.87.2.160. Heart. 2002. PMID: 11796559 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical