Components-of-variance models and multiple-bootstrap experiments: an alternative method for random-effects, receiver operating characteristic analysis
- PMID: 10803614
- DOI: 10.1016/s1076-6332(00)80008-2
Components-of-variance models and multiple-bootstrap experiments: an alternative method for random-effects, receiver operating characteristic analysis
Abstract
Rationale and objectives: The purpose of this study was to develop an alternative approach to random-effects, receiver operating characteristic analysis inspired by a general formulation of components-of-variance models. The alternative approach is a higher-order generalization of the Dorfman, Berbaum, and Metz (DBM) approach that yields additional information on the variance structure of the problem.
Materials and methods: Six population experiments were designed to determine the six variance components in the DBM model. For practical problems, in which only a finite set of readers and patients are available, six analogous bootstrap experiments may be substituted for the population experiments to estimate the variance components. Monte Carlo simulations were performed on the population experiments, and those results were compared with the corresponding multiple-bootstrap estimates and those obtained with the DBM approach. Confidence intervals on the difference of ROC parameters for competing diagnostic modalities were estimated, and corresponding comparisons were made.
Results: For mean values, the agreement of present estimates of variance structures with population results was excellent and, when suitably weighted and mixed, similar to or closer than that with the DBM method. For many variance structures, the confidence intervals in this study for the difference in ROC area between modalities were comparable to those with the DBM method. When reader variability was large, however, mean confidence intervals from this study were tighter than those with the DBM method and closer to population results.
Conclusion: The jackknife approach of DBM provides a linear approximation to receiver-operating-characteristic statistics that are intrinsically nonlinear. The multiple-bootstrap technique of this study, however, provides a more general, nonparametric, maximum-likelihood approach. It also yields estimates of the variance structure previously unavailable.
Similar articles
-
Multireader, multicase receiver operating characteristic methodology: a bootstrap analysis.Acad Radiol. 1995 Jul;2(7):626-33. doi: 10.1016/s1076-6332(05)80129-1. Acad Radiol. 1995. PMID: 9419615
-
Monte Carlo validation of the Dorfman-Berbaum-Metz method using normalized pseudovalues and less data-based model simplification.Acad Radiol. 2005 Dec;12(12):1534-41. doi: 10.1016/j.acra.2005.07.012. Acad Radiol. 2005. PMID: 16321742 Free PMC article.
-
A marginal model approach for analysis of multi-reader multi-test receiver operating characteristic (ROC) data.Biostatistics. 2005 Apr;6(2):303-12. doi: 10.1093/biostatistics/kxi011. Biostatistics. 2005. PMID: 15772108
-
Analysis of uncertainties in estimates of components of variance in multivariate ROC analysis.Acad Radiol. 2001 Jul;8(7):616-22. doi: 10.1016/S1076-6332(03)80686-4. Acad Radiol. 2001. PMID: 11450962
-
Prediction accuracy of a sample-size estimation method for ROC studies.Acad Radiol. 2010 May;17(5):628-38. doi: 10.1016/j.acra.2010.01.007. Acad Radiol. 2010. PMID: 20380980 Free PMC article.
Cited by
-
Pioneers in Medical Imaging: Honoring the Memory of Robert F. Wagner.J Med Imaging (Bellingham). 2014 Oct;1(3):031001. doi: 10.1117/1.JMI.1.3.031001. J Med Imaging (Bellingham). 2014. PMID: 26158043 Free PMC article. No abstract available.
-
Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design.Biometrics. 2014 Dec;70(4):1033-41. doi: 10.1111/biom.12240. Epub 2014 Oct 29. Biometrics. 2014. PMID: 25355470 Free PMC article.
-
Evaluating computer-aided detection algorithms.Med Phys. 2007 Jun;34(6):2024-38. doi: 10.1118/1.2736289. Med Phys. 2007. PMID: 17654906 Free PMC article.
-
Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: results from independently conducted FROC∕ROC studies in mammography.Med Phys. 2012 Oct;39(10):5917-29. doi: 10.1118/1.4747262. Med Phys. 2012. PMID: 23039631 Free PMC article.
-
Comparison of 3D free-breathing coronary MR angiography and 64-MDCT angiography for detection of coronary stenosis in patients with high calcium scores.AJR Am J Roentgenol. 2007 Dec;189(6):1326-32. doi: 10.2214/AJR.07.2805. AJR Am J Roentgenol. 2007. PMID: 18029867 Free PMC article.