Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Apr;45(4):317-22.

Clinical vs. sonographic estimate of birth weight in term parturients. A randomized clinical trial

Affiliations
  • PMID: 10804488
Clinical Trial

Clinical vs. sonographic estimate of birth weight in term parturients. A randomized clinical trial

N W Hendrix et al. J Reprod Med. 2000 Apr.

Abstract

Objective: To determine the relative accuracy of clinical and sonographic birth weight estimation among term parturients (> or = 37 weeks) and to assess the performance of the two techniques in identifying newborns with weights of < 2,500 g vs. > or = 2,500 g or < 2,500 g vs. at least 4,000 g.

Study design: The sample size for this randomized clinical trial was based on the assumption that 50% of clinical predictions are within 10% of birth weight. Thus, 700 parturients were necessary to show a difference of 10% with sonographic estimates (alpha = .05, beta = .02). Inclusion criteria were singletons with a reliable gestational age of > or = 37 weeks, admitted for delivery and with no known fetal anomalies. Physicians who were unaware of previous sonographic estimates obtained the estimates. Student t and chi 2 tests were used; relative risk (RR) and 95% confidence intervals (CIs) were calculated. Receiver-operating characteristic (ROC) curves were constructed to compare the two techniques' ability to differentiate between abnormal (birth weight < 2,500 g and > 4,000 g) and normal (2,500-3,999 g). P < .05 was considered significant.

Results: Over 30 months, 758 term parturients were recruited; of them, 391 had clinical estimates and 367, sonographic. The two groups were similar in gestational age, prepregnancy and intrapartum body mass index, station of the presenting part, actual birth weight and frequency of newborns with weights < 2,500 g or > or = 4,000 g. Predictions based on clinical examination were significantly more likely to be within 10% of actual weight (58%) than those derived from ultrasound examination (32%; P < .0001; RR, 1.65; 95% CI, 1.43, 1.69). The areas under the ROC curves indicated that both techniques had a similar ability to differentiate normally and abnormally grown fetuses (P > .05).

Conclusion: Among term parturients, clinical estimates had significantly higher accuracy than ones derived sonographically.

PubMed Disclaimer

Publication types

LinkOut - more resources