Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography

Affiliations
Multicenter Study

Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography

Q Cao et al. Eur Heart J. 2000 Jun.

Abstract

Aims: To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects.

Methods: Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter closure of their atrial septal defects at a mean+/-SD age of 30. 8+/-18.6 years (range 3.7-65.9 years) and mean weight of 56.6+/-25.5 kg (range 12.9-99 kg) using two Amplatzer devices implanted simultaneously via two separate delivery systems. During catheterization, two dimensional transoesophageal echocardiography was performed in all but one patient, during and after transcatheter closure, while three dimensional transoesophageal echocardiography was performed in six patients before and after transcatheter closure.

Results: Forty-four devices were deployed in all patients to close 45 defects (one patient with three defects closed by two devices). Two dimensional transoesophageal echocardiography was helpful in selection and in guiding correct deployment of the devices. The mean size of the larger defect, as measured by transoesophageal echocardiography was 12.8+/-5.9 mm and the mean size of the smaller defect was 6.6+/-3.0 mm. The mean size of the larger devices was 15+/-7.5 mm, and 8.4+/-3.7 mm for the smaller. Three dimensional transoesophageal echocardiography provided superior imaging and demonstrated the number, shape and the surrounding structures of the atrial septal defects in one single view. The median fluoroscopy time was 28.7 min. Device embolization with successful catheter retrieval occurred in one patient. Forty-four devices were evaluated by colour Doppler transoesophageal echocardiography immediately after the catheterization with a successful closure rate of 97.7%. On follow-up colour Doppler transthoracic echocardiography demonstrated successful closure in 97.5% at 3 months.

Conclusions: The use of more than one Amplatzer septal occluder to close multiple atrial septal defects is safe and effective. The use of two- and three-dimensional transoesophageal echocardiography provided useful information for transcatheter closure of multiple atrial septal defects using two devices. Three-dimensional transoesophageal echocardiography enhanced our ability to image and understand the spatial relationship of the atrial septal defect anatomy.