Optoelectronic plethysmography in intensive care patients
- PMID: 10806152
- DOI: 10.1164/ajrccm.161.5.9903024
Optoelectronic plethysmography in intensive care patients
Abstract
We used optoelectronic plethysmography to study 11 normal subjects during quiet and deep breathing, six sedated and paralyzed patients with acute lung injury and acute respiratory distress syndrome (ALI/ARDS) receiving continuous positive pressure ventilation (CPPV) (positive end-expiratory pressure [PEEP] = 10 cm H(2)O, tidal volume [VT] = 300, 600, 900 ml), and seven ALI/ARDS patients receiving pressure support ventilation (PSV) (PEEP 10 cm H(2)O, pressure support = 5, 10, 15, 25 cm H(2)O). The volumes measured using optoelectronic plethysmography were compared with measurements taken using spirometry and pneumotachography. The three methods were highly correlated. The discrepancies found were 1.7 +/- 5.9%, -1.6 +/- 5.4%, and 4.9 +/- 6.4% when comparing optoelectronic plethysmography with spirometry, optoelectronic plethysmography with pneumotachography, and spirometry with pneumotachography, respectively. Accuracy of the compartmentalization procedure (upper thorax, lower thorax, and abdomen) was assessed by calculating compartmental volume changes during isovolume maneuvers. The discrepancy from the ideal zero line was -2.1 +/- 48.3 ml. Abdominal contribution to inspired volume was greater for normal subjects than for PSV patients (63 +/- 11% versus 43 +/- 14%, p < 0.001). It decreased with VT for normal subjects (48.5 +/- 15%, p < 0.05), whereas it increased for CPPV patients (61 +/- 10%, p < 0.05). No significant distribution differences were found between 5 and 25 cm H(2)O PSV. We conclude that optoelectronic plethysmography is a feasible technique able to provide unique data on the distribution of chest wall volume changes in intensive care patients.
Similar articles
-
Evaluation of respiratory inductive plethysmography in controlled ventilation: measurement of tidal volume and PEEP-induced changes of end-expiratory lung volume.Chest. 1998 Feb;113(2):443-51. doi: 10.1378/chest.113.2.443. Chest. 1998. PMID: 9498965
-
Alterations of lung and chest wall mechanics in patients with acute lung injury: effects of positive end-expiratory pressure.Am J Respir Crit Care Med. 1995 Aug;152(2):531-7. doi: 10.1164/ajrccm.152.2.7633703. Am J Respir Crit Care Med. 1995. PMID: 7633703
-
Tracheal gas insufflation. Limits of efficacy in adults with acute respiratory distress syndrome.Am J Respir Crit Care Med. 2000 Aug;162(2 Pt 1):387-92. doi: 10.1164/ajrccm.162.2.9910111. Am J Respir Crit Care Med. 2000. PMID: 10934058
-
ARDS and PV curves: the inseparable duet?Intensive Care Med. 2000 Jan;26(1):1-2. doi: 10.1007/s001340050001. Intensive Care Med. 2000. PMID: 10663270 Review. No abstract available.
-
Optoelectronic Plethysmography in Clinical Practice and Research: A Review.Respiration. 2017;93(5):339-354. doi: 10.1159/000462916. Epub 2017 Mar 23. Respiration. 2017. PMID: 28329750 Review.
Cited by
-
A technique to measure tidal volume during noninvasive respiratory support by continuous-flow helmet CPAP.J Clin Monit Comput. 2023 Dec;37(6):1473-1479. doi: 10.1007/s10877-023-01034-0. Epub 2023 Jun 17. J Clin Monit Comput. 2023. PMID: 37329389 Free PMC article.
-
Development of a bio-inspired mechatronic chest wall simulator for evaluating the performances of opto-electronic plethysmography.Open Biomed Eng J. 2014 Dec 19;8:120-30. doi: 10.2174/1874120701408010120. eCollection 2014. Open Biomed Eng J. 2014. PMID: 25624954 Free PMC article.
-
In Vivo Measurement of Tidal Volume During Non-invasive Respiratory Support by Continuous-Flow Helmet CPAP.Ann Biomed Eng. 2024 Sep;52(9):2546-2555. doi: 10.1007/s10439-024-03545-6. Epub 2024 Jun 17. Ann Biomed Eng. 2024. PMID: 38886251 Free PMC article.
-
Reliability and validity of measuring respiration movement using a wearable strain sensor in healthy subjects.J Phys Ther Sci. 2017 Sep;29(9):1543-1547. doi: 10.1589/jpts.29.1543. Epub 2017 Sep 15. J Phys Ther Sci. 2017. PMID: 28931984 Free PMC article.
-
Investigating Stroke Effects on Respiratory Parameters Using a Wearable Device: A Pilot Study on Hemiplegic Patients.Sensors (Basel). 2022 Sep 5;22(17):6708. doi: 10.3390/s22176708. Sensors (Basel). 2022. PMID: 36081165 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources