A clinical evaluation of some factors affecting image quality in panoramic radiography
- PMID: 10808220
- DOI: 10.1038/sj/dmfr/4600505
A clinical evaluation of some factors affecting image quality in panoramic radiography
Abstract
Aim: To evaluate the suitability of panoramic radiographs obtained with two different machines for clinical use.
Material and methods: Three observers assessed 111 pairs of panoramic radiographs taken with the Scanora (Soredex, Orion Corp., Helsinki, Finland) programme 001, and the Orthophos Plus (Sirona, Bensheim, Germany), programme P1 respectively, for visualisation of seven anatomical structures on each side, on a 5-point scale where 1 = very good. The median values were computed and a descriptive analysis performed. Interrater and intrarater agreement were expressed as weighted kappa.
Results: The median values of both Scanora and Orthophos radiographs were the same, scoring 2. The intra- and inter-observer agreement was generally poor and similar for both machines.
Conclusions: The two panoramic machines were both given good ratings for evaluation of anatomical structures. The differences were very small and suggest that both machines are suitable for clinical use.
Similar articles
-
The effect of dose reduction on the detection of anatomical structures on panoramic radiographs.Dentomaxillofac Radiol. 2006 Jul;35(4):271-7. doi: 10.1259/dmfr/16653683. Dentomaxillofac Radiol. 2006. PMID: 16798925 Clinical Trial.
-
A comparison of the diagnostic utility of two image receptors for panoramic radiography.Dentomaxillofac Radiol. 2000 Jan;29(1):57-60. doi: 10.1038/sj/dmfr/4600495. Dentomaxillofac Radiol. 2000. PMID: 10654038 Clinical Trial.
-
Image quality in panoramic radiography.Dentomaxillofac Radiol. 1995 Feb;24(1):17-22. doi: 10.1259/dmfr.24.1.8593902. Dentomaxillofac Radiol. 1995. PMID: 8593902
-
Panoramic radiography in dental diagnostics.Swed Dent J Suppl. 1996;119:1-26. Swed Dent J Suppl. 1996. PMID: 8971997 Review.
-
Digital panoramic and extraoral imaging.Dent Clin North Am. 1993 Oct;37(4):541-51. Dent Clin North Am. 1993. PMID: 8224331 Review.
Cited by
-
Subjective image quality of digital panoramic radiographs displayed on monitor and printed on various hardcopy media.Clin Oral Investig. 2004 Mar;8(1):25-9. doi: 10.1007/s00784-003-0239-y. Epub 2003 Dec 2. Clin Oral Investig. 2004. PMID: 14652733
-
Correlation between spatial resolution and ball distortion rate of panoramic radiography.BMC Med Imaging. 2020 Jun 19;20(1):68. doi: 10.1186/s12880-020-00472-5. BMC Med Imaging. 2020. PMID: 32560631 Free PMC article.
-
Style harmonization of panoramic radiography using deep learning.Oral Radiol. 2025 Jan;41(1):111-119. doi: 10.1007/s11282-024-00782-2. Epub 2024 Oct 29. Oral Radiol. 2025. PMID: 39470914
-
Image quality assessment of pre-processed and post-processed digital panoramic radiographs in paediatric patients with mixed dentition.Imaging Sci Dent. 2018 Dec;48(4):261-268. doi: 10.5624/isd.2018.48.4.261. Epub 2018 Dec 20. Imaging Sci Dent. 2018. PMID: 30607350 Free PMC article.