Accuracy and precision of the i-STAT portable clinical analyzer: an analytical point of view
- PMID: 10808706
Accuracy and precision of the i-STAT portable clinical analyzer: an analytical point of view
Abstract
The introduction of a new point-of-care testing (POCT) instrument into the market affects medical practice and laboratory services. The i-STAT is designed to improve the speed in the decision making of the medical profession. However, reliability of results would ensure the quality of laboratory data. We, therefore, made an evaluation of the performance of i-STAT using a disposable cartridge EG7 + which is capable of measuring pH, pO2, pCO2 (blood gas), Sodium, Potassium (Electrolytes), Ionized calcium and Hematocrit with only 10 microliters of lithium heparinized blood in 2 minutes. The results were compared with those obtained from routine methods. The results were found to be accurate, precise and correlated with acceptable methods used routinely in the laboratory.
Similar articles
-
[Evaluation of portable point of care instrument: the i-Stat . Report of 7,000 analyses].Ann Biol Clin (Paris). 2002 Mar-Apr;60(2):153-64. Ann Biol Clin (Paris). 2002. PMID: 11937440 French.
-
Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.Ann Clin Lab Sci. 2002 Summer;32(3):231-43. Ann Clin Lab Sci. 2002. PMID: 12175085
-
Evaluation of a portable clinical analyzer in a veterinary hospital setting.J Am Vet Med Assoc. 1998 Sep 1;213(5):691-4. J Am Vet Med Assoc. 1998. PMID: 9731265
-
New whole blood analyzers and their impact on cardiac and critical care.Crit Rev Clin Lab Sci. 1993;30(2):153-202. doi: 10.3109/10408369309084667. Crit Rev Clin Lab Sci. 1993. PMID: 8363743 Review.
-
Robotics and automated workstations for rapid response testing.Am J Clin Pathol. 1995 Oct;104(4 Suppl 1):S26-32. Am J Clin Pathol. 1995. PMID: 7484946 Review.
Cited by
-
Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.J Extra Corpor Technol. 2008 Mar;40(1):57-60. J Extra Corpor Technol. 2008. PMID: 18389666 Free PMC article.
-
Bedside ABG, electrolytes, lactate and procalcitonin in emergency pediatrics.Int J Crit Illn Inj Sci. 2014 Jul;4(3):247-52. doi: 10.4103/2229-5151.141467. Int J Crit Illn Inj Sci. 2014. PMID: 25337488 Free PMC article.
-
Lack of arterial PO2 downregulation in Atlantic salmon (Salmo salar L.) during long-term normoxia and hyperoxia.Fish Physiol Biochem. 2010 Dec;36(4):1087-95. doi: 10.1007/s10695-010-9386-7. Epub 2010 Mar 11. Fish Physiol Biochem. 2010. PMID: 20221686
Publication types
MeSH terms
LinkOut - more resources
Medical