The role of in process qualification in quality improvement of the haemonetics MCS plus leucodepleted platelet concentrate
- PMID: 10831919
- DOI: 10.1016/s0955-3886(00)00044-8
The role of in process qualification in quality improvement of the haemonetics MCS plus leucodepleted platelet concentrate
Abstract
With the implementation of universal leucodepletion in UK all leucodepletion processes have gone through a standard process qualification and quality improvement. The Haemonetics MCS system is a well established automated platelet collection system for the production of double dose leucoreduced platelet concentrate (WBC approximately 70x10(6)/dose). Recently an automated post collection filtration harness system has been introduced (MCS plus LDP) in which platelets are filtered, using an in-line PALL polyester filter (LRFH6 PALL) to reduce the WBC level to below 5x10(6) WBC/dose. This system passed our Phase I evaluation process based on 20-40 runs. However, some changes in the final volume of the products were needed to conform to national guidelines. Large scale trials using the new volume adjusted protocol revealed occasional failure in the leucocyte content. Therefore, 100% testing had to be implemented on all products. A national evaluation was carried out to determine whether changing the filter to a more efficacious one, the LRFXL (PALL) or slowing the filtration flow rate can influence the overall outcome. To reduce donor variability, known donor population were used with identical apheresis conditions. A more consistent and systematic drop in leucocyte content was observed by reducing the flow rate whereas a similar failure (i.e. 1-3%) rate was found both in controls and LRFXL when using the standard head pressure, which is recommended by the manufacturer. A similar failure rate was found using three different low leucocyte counting technologies (Nageotte, flow cytometry and Imagn 2000). It is recommended that a process qualification/validation program should be implemented when even a small modification in the collection system is introduced.
Similar articles
-
Studies on the improvement of leucodepletion performance of the Haemonetics MCS+ for production of leucodepleted platelet concentrate.Platelets. 2001 Aug;12(5):298-301. doi: 10.1080/09537100120068189. Platelets. 2001. PMID: 11487382
-
The quality of MCS+ version C2 double dose platelet concentrate with leucodepletion through a continuous filtration process.Transfus Apher Sci. 2002 Feb;26(1):37-41. doi: 10.1016/s1473-0502(01)00143-4. Transfus Apher Sci. 2002. PMID: 11931376
-
Improved removal of white cells with minimal platelet loss by filtration of apheresis platelets during collection.Transfusion. 1999 Jan;39(1):74-82. doi: 10.1046/j.1537-2995.1999.39199116898.x. Transfusion. 1999. PMID: 9920170
-
Platelet storage lesion: an update on the impact of various leukoreduction processes on the biological response modifiers.Transfus Apher Sci. 2006 Feb;34(1):125-30. doi: 10.1016/j.transci.2005.09.002. Epub 2005 Dec 20. Transfus Apher Sci. 2006. PMID: 16376152 Review.
-
UK strategy for process qualification/validation: from concept to practical implementation.Transfus Sci. 2000 Jun;22(3):203-6. doi: 10.1016/s0955-3886(00)00041-2. Transfus Sci. 2000. PMID: 10831923 Review.
Cited by
-
Therapeutic Plateletpheresis in Patients With Thrombocytosis: Gender, Hemoglobin Before Apheresis Significantly Affect Collection Efficiency.Front Med (Lausanne). 2021 Dec 24;8:762419. doi: 10.3389/fmed.2021.762419. eCollection 2021. Front Med (Lausanne). 2021. PMID: 35004735 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources