. 2000 Jun;38(6):2395-7.
doi: 10.1128/JCM.38.6.2395-2397.2000.

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium

Affiliations
Clinical Trial

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium

A Somoskövi et al. J Clin Microbiol. 2000 Jun.

Abstract

Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) medium. The mean time to detection of M. tuberculosis in smear-positive specimens was 12.6 days for BACTEC MGIT 960 medium, 13.8 days for BACTEC 12B medium, and 20.1 days for LJ medium, and in smear-negative specimens it was 15.8 days for BACTEC MGIT 960 medium, 17.7 days for BACTEC 12B medium, and 42.2 days for LJ medium. The rates of contamination were 3.7, 2.9, and 1.2% for the BACTEC MGIT 960, BACTEC 12B, and LJ media, respectively. In conclusion, the nonradiometric, fully automated 7-ml BACTEC MGIT 960 system can be considered a viable alternative to the semiautomated, radiometric BACTEC 460 TB system.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Benjamin W H, Jr, Waites K B, Beverly A, Gibbs L, Waller M, Nix S, Moser S A, Willert M. Comparison of the MB/BacT system with a revised antibiotic supplement kit to the Bactec 460 system for detection of mycobacteria in clinical specimens. J Clin Microbiol. 1998;36:3234–3238. - PMC - PubMed
    1. Hanna B A, Ebrahimzadeh A, Elliot B, Morgan M A, Novak S M, Rüsch-Gerdes S, Acio M, Dunbar D F, Holmes T M, Rexer C H, Savthyakumar C, Vannier A M. Multicenter evaluation of the Bactec MGIT 960 system for recovery of mycobacteria. J Clin Microbiol. 1999;37:748–752. - PMC - PubMed
    1. Kent P T, Kubica G P. Public health mycobacteriology. A guide for a level III laboratory. Atlanta, Ga: Centers for Disease Control; 1985.
    1. Pfyffer G E, Welscher H-M, Kissling P, Cieslak C, Casal M J, Gutierrez J, Rüsch-Gerdes S. Comparison of the Mycobacteria Growth Indicator Tube (MGIT) with radiometric and solid culture for recovery of acid-fast bacilli. J Clin Microbiol. 1997;35:364–368. - PMC - PubMed
    1. Piersimoni C, Scarparo C, Cichero P, Del Pezzo M, Covelli I, Gesu G, Nista D, Scagnelli M, Mandler F. Multicenter evaluation of the MB-Redox medium compared with radiometric Bactec system, Mycobacteria Growth Indicator Tube (MGIT), and Löwenstein-Jensen medium for detection and recovery of acid-fast bacilli. Diagn Microbiol Infect Dis. 1999;34:293–299. - PubMed

Publication types

MeSH terms

LinkOut - more resources