Clinical Trial
. 2000 Jun;92(6):1531-6.
doi: 10.1097/00000542-200006000-00008.

Amniotic fluid removal during cell salvage in the cesarean section patient

Affiliations
Clinical Trial

Amniotic fluid removal during cell salvage in the cesarean section patient

J H Waters et al. Anesthesiology. 2000 Jun.

Abstract

Background: Cell salvage has been used in obstetrics to a limited degree because of a fear of amniotic fluid embolism. In this study, cell salvage was combined with blood filtration using a leukocyte depletion filter. A comparison of this washed, filtered product was then made with maternal central venous blood.

Methods: The squamous cell concentration, lamellar body count, quantitative bacterial colonization, potassium level, and fetal hemoglobin concentration were measured in four sequential blood samples collected from 15 women undergoing elective cesarean section. The blood samples collected included (1) unwashed blood from the surgical field (prewash), (2) washed blood (postwash), (3) washed and filtered blood (postfiltration), and (4) maternal central venous blood drawn from a femoral catheter at the time of placental separation.

Results: Significant reductions in the following parameters were seen when the postfiltration samples were compared to the prewash samples (median [25th-75th percentile]): squamous cell concentration (0.0 [0.0-0.1 counts/high-powered field (HPF)] vs. 8.3 counts/HPF [4. 0-10.5 counts/HPF], P < 0.05); bacterial contamination (0.1 [0.0-0. 2] vs. 3.0 [0.6-7.7] colony-forming units (CFU)/ml, P < 0.01); and lamellar body concentration (0.0 [0.0-1.0] vs. 22.0 [18.5-29.5] thousands/microl, P < 0.01). No significant differences existed between the postfiltration and maternal samples for each of these parameters. Fetal hemoglobin was in higher concentrations in the postfiltration sample when compared with maternal blood (1.9 [1.1-2. 5] vs. 0.5% [0.3-0.7] ). Potassium levels were significantly less in the postfiltration sample when compared with maternal (1.4 [1.0-1.5] vs. 3.8 mEq/l [3.7-4.0]).

Conclusions: Leukocyte depletion filtering of cell-salvaged blood obtained from cesarean section significantly reduces particulate contaminants to a concentration equivalent to maternal venous blood.

PubMed Disclaimer

Comment in

Publication types