Continuous localization of cardiac activation sites using a database of multichannel ECG recordings
- PMID: 10851812
- DOI: 10.1109/10.841340
Continuous localization of cardiac activation sites using a database of multichannel ECG recordings
Abstract
Monomorphic ventricular tachycardia and ventricular extrasystoles have a specific exit site that can be localized using the multichannel surface electrocardiogram (ECG) and a database of paced ECG recordings. An algorithm is presented that improves on previous methods by providing a continuous estimate of the coordinates of the exit site instead of selecting one out of 25 predetermined segments. The accuracy improvement is greatest, and most useful, when adjacent pacing sites in individual patients are localized relative to each other. Important advantages of the new method are the objectivity and reproducibility of the localization results.
Similar articles
-
A novel algorithm for determining endocardial VT exit site from 12-lead surface ECG characteristics in human, infarct-related ventricular tachycardia.J Cardiovasc Electrophysiol. 2007 Feb;18(2):161-8. doi: 10.1111/j.1540-8167.2007.00721.x. J Cardiovasc Electrophysiol. 2007. PMID: 17338765
-
Automatic QRS onset and offset detection for body surface QRS integral mapping of ventricular tachycardia.IEEE Trans Biomed Eng. 1994 Sep;41(9):830-6. doi: 10.1109/10.312090. IEEE Trans Biomed Eng. 1994. PMID: 7959810
-
Statistical accuracy of a moving equivalent dipole method to identify sites of origin of cardiac electrical activation.IEEE Trans Biomed Eng. 2003 Dec;50(12):1360-70. doi: 10.1109/TBME.2003.819849. IEEE Trans Biomed Eng. 2003. PMID: 14656065
-
Clinical use of body surface potential mapping in cardiac arrhythmias.Anadolu Kardiyol Derg. 2007 Jul;7 Suppl 1:8-10. Anadolu Kardiyol Derg. 2007. PMID: 17584668 Review.
-
Left ventricular outflow tract tachycardia including ventricular tachycardia from the aortic cusps and epicardial ventricular tachycardia.Herz. 2007 May;32(3):226-32. doi: 10.1007/s00059-007-2977-0. Herz. 2007. PMID: 17497256 Review.
Cited by
-
Prospective Assessment of an Automated Intraprocedural 12-Lead ECG-Based System for Localization of Early Left Ventricular Activation.Circ Arrhythm Electrophysiol. 2020 Jul;13(7):e008262. doi: 10.1161/CIRCEP.119.008262. Epub 2020 Jun 15. Circ Arrhythm Electrophysiol. 2020. PMID: 32538133 Free PMC article.
-
A Novel Model Based on Spatial and Morphological Domains to Predict the Origin of Premature Ventricular Contraction.Front Physiol. 2021 Feb 24;12:641358. doi: 10.3389/fphys.2021.641358. eCollection 2021. Front Physiol. 2021. PMID: 33716789 Free PMC article.
-
Learning Domain Shift in Simulated and Clinical Data: Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms.IEEE Trans Med Imaging. 2019 May;38(5):1172-1184. doi: 10.1109/TMI.2018.2880092. Epub 2018 Nov 9. IEEE Trans Med Imaging. 2019. PMID: 30418900 Free PMC article.
-
Guidance for catheter ablation of ventricular arrhythmia.Med Biol Eng Comput. 2009 Mar;47(3):241-3. doi: 10.1007/s11517-008-0428-6. Epub 2009 Jan 10. Med Biol Eng Comput. 2009. PMID: 19137349 No abstract available.
-
Sequential Factorized Autoencoder for Localizing the Origin of Ventricular Activation From 12-Lead Electrocardiograms.IEEE Trans Biomed Eng. 2020 May;67(5):1505-1516. doi: 10.1109/TBME.2019.2939138. Epub 2019 Sep 3. IEEE Trans Biomed Eng. 2020. PMID: 31494539 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources