Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas
- PMID: 10853815
- DOI: 10.1007/s002590050546
Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas
Abstract
Increasingly hospitals are showing an interest in developing their imaging services to include positron emission tomography (PET). There is therefore a need to be aware of the radiation doses to critical groups. To assess the effective whole-body dose received by technologists within our dedicated PET centre, each staff member was issued with a dose rate meter, and was instructed to record the time spent in contact with any radioactive source, the dose received per working day and the daily injected activity. On average each technologist administered 831 MBq per day. The mean whole-body dose per MBq injected was 0.02 microSv/MBq(-1). The average time of close contact (<2.0 m) with a radioactive source per day was 32 min. The average effective dose per minute close contact was 0.5 microSv/min(-1), which resulted in a mean daily effective dose of 14.4 microSv. No technologist received greater than 60 microSv (the current UK limit for non-classified workers) in any one day, and in general doses received were less than 24 microSv, the daily dose corresponding to the proposed new annual limit for non-classified workers of 6.0 mSv per annum. However, we recognise that the layout of nuclear medicine departments will not mirror our own. We therefore measured the instantaneous dose rates at 0.1, 0.5, 1.0 and 2.0 m from the mid-thorax on 115 patients immediately after injection, to provide estimates of the likely effective doses that might be received by technologists operating dual-headed coincidence detection systems, and others coming into contact in the waiting room with patients who have been injected with fluorine-18 fluorodeoxyglucose. The mean (95th percentile) dose rates measured at the four aforementioned distances were 391.7 (549.5), 127.0 (199.8), 45.3 (70.0) and 17.1 (30.0) microSv/h(-1), respectively. A number of situations have been modelled showing that, with correct planning, FDG studies should not significantly increase the effective doses to technologists. However, one possible area of concern is that, depending on the number of patients in a waiting area at any one time, accompanying persons may approach the limits set by the new UK IRR 1999 regulations for members of the public.
Similar articles
-
Are restrictions to behaviour of patients required following fluorine-18 fluorodeoxyglucose positron emission tomographic studies?Eur J Nucl Med. 1999 Feb;26(2):121-8. doi: 10.1007/s002590050367. Eur J Nucl Med. 1999. PMID: 9933345
-
Technologist radiation exposure in routine clinical practice with 18F-FDG PET.J Nucl Med Technol. 2005 Sep;33(3):175-9. J Nucl Med Technol. 2005. PMID: 16145226
-
Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose.Eur J Nucl Med. 1997 Nov;24(11):1380-9. doi: 10.1007/s002590050164. Eur J Nucl Med. 1997. PMID: 9371871
-
Potential biomarkers of chronic low-dose radiation exposure for nuclear medicine technologists.Int J Radiat Biol. 2025;101(5):453-466. doi: 10.1080/09553002.2025.2470225. Epub 2025 Mar 18. Int J Radiat Biol. 2025. PMID: 40099925 Free PMC article. Review.
-
[Toxicity and radiation dosage of 2-(18F)-2-desoxy-D-glucose in positron emission tomography].Acta Med Austriaca. 1998;25(1):1-6. Acta Med Austriaca. 1998. PMID: 9576017 Review. German.
Cited by
-
Instantaneous exposure to nuclear medicine staff involved in PET-CT imaging in developing countries: experience from a tertiary care centre in India.Jpn J Radiol. 2012 May;30(4):291-5. doi: 10.1007/s11604-011-0045-4. Epub 2012 Jan 14. Jpn J Radiol. 2012. PMID: 22246804
-
Automated Injectors versus Manual Administration: A Comparative Analysis of Radiation Exposure Reduction in 18 F-FDG Delivery.World J Nucl Med. 2024 Oct 16;24(1):36-46. doi: 10.1055/s-0044-1791781. eCollection 2025 Mar. World J Nucl Med. 2024. PMID: 39959151 Free PMC article.
-
Measurement of absorbed doses in organs of medical staff at (18)F-FDG pet examination.Radiol Phys Technol. 2010 Jan;3(1):34-9. doi: 10.1007/s12194-009-0073-2. Epub 2009 Nov 3. Radiol Phys Technol. 2010. PMID: 20821099
-
Radiation Exposure to the Personnel Performing Robotic Arm-Assisted Positron Emission Tomography/Computed Tomography-Guided Biopsies.Indian J Nucl Med. 2018 Jul-Sep;33(3):209-213. doi: 10.4103/ijnm.IJNM_31_18. Indian J Nucl Med. 2018. PMID: 29962716 Free PMC article.
-
Designing of High-Volume PET/CT Facility with Optimal Reduction of Radiation Exposure to the Staff: Implementation and Optimization in a Tertiary Health Care Facility in India.World J Nucl Med. 2015 Sep-Dec;14(3):189-96. doi: 10.4103/1450-1147.163252. World J Nucl Med. 2015. PMID: 26420990 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical