The initial fixation of the press-fit acetabular shell--clinical observation and experimental study
- PMID: 10853904
- DOI: 10.1007/s004020050473
The initial fixation of the press-fit acetabular shell--clinical observation and experimental study
Abstract
The initial solid fixation of an uncemented acetabular component affects the amount of bone ingrowth. We had several problems with broken screws in cases of acetabular revision. In recent years, the development of uncemented components without screws has attempted to improve these problems. We started to use "press-fit"-type acetabular shells in November 1996. Our thirty cases undergoing 2 mm under-reaming show good initial stability. The aim of our biomechanical study was to assess the most suitable degree of under-reaming of the bony acetabulum for the implantation of an uncemented hemispherical porous coated component.
Similar articles
-
Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.Eur J Orthop Surg Traumatol. 2015 Apr;25(3):497-502. doi: 10.1007/s00590-014-1571-4. Epub 2014 Nov 25. Eur J Orthop Surg Traumatol. 2015. PMID: 25421640 Free PMC article.
-
[Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].Acta Chir Orthop Traumatol Cech. 2002;69(1):8-15. Acta Chir Orthop Traumatol Cech. 2002. PMID: 11951572 German.
-
Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty. An in vitro comparison of different methods of initial acetabular component fixation.J Arthroplasty. 1992 Dec;7(4):537-47. doi: 10.1016/s0883-5403(06)80076-8. J Arthroplasty. 1992. PMID: 1479374
-
The jumbo acetabular component for acetabular revision: Curtain Calls and Caveats.Bone Joint J. 2016 Jan;98-B(1 Suppl A):64-7. doi: 10.1302/0301-620X.98B1.36139. Bone Joint J. 2016. PMID: 26733644 Review.
-
Implant choices, technique, and results in revision acetabular surgery: a review.Hip Int. 2012 May-Jun;22(3):235-47. doi: 10.5301/HIP.2012.9281. Hip Int. 2012. PMID: 22740277 Review.
Cited by
-
Acetabular Wall Weakening in Total Hip Arthroplasty: A Pilot Study.Pathophysiology. 2023 Mar 23;30(2):83-91. doi: 10.3390/pathophysiology30020008. Pathophysiology. 2023. PMID: 37092522 Free PMC article.
-
Differences in acoustic parameters of hammering sounds between successful and unsuccessful initial cementless cup press-fit fixation in total hip arthroplasty.Bone Jt Open. 2024 Mar 1;5(3):154-161. doi: 10.1302/2633-1462.53.BJO-2023-0160.R1. Bone Jt Open. 2024. PMID: 38423101 Free PMC article.
-
The use of acetabular screws in total hip arthroplasty and its influence on wear and periacetabular osteolysis in the long-term follow-up.Int Orthop. 2022 Apr;46(4):717-722. doi: 10.1007/s00264-021-05219-7. Epub 2021 Sep 28. Int Orthop. 2022. PMID: 34581866 Free PMC article.
-
Acetabular loosening using an extended offset polyethylene liner.Clin Orthop Relat Res. 2009 Jan;467(1):188-93. doi: 10.1007/s11999-008-0479-x. Epub 2008 Sep 10. Clin Orthop Relat Res. 2009. PMID: 18781370 Free PMC article.
-
Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.Eur J Orthop Surg Traumatol. 2015 Apr;25(3):497-502. doi: 10.1007/s00590-014-1571-4. Epub 2014 Nov 25. Eur J Orthop Surg Traumatol. 2015. PMID: 25421640 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical