Quantitative microscopy after fluorescence in situ hybridization - a comparison between repeat-depleted and non-depleted DNA probes
- PMID: 10889276
- DOI: 10.1016/s0165-022x(00)00047-6
Quantitative microscopy after fluorescence in situ hybridization - a comparison between repeat-depleted and non-depleted DNA probes
Abstract
Complex probes used in fluorescence in situ hybridization (FISH) usually contain repetitive DNA sequences. For chromosome painting, in situ suppression of these repetitive DNA sequences has been well established. Standard painting protocols require large amounts of an unlabeled 'blocking agent', for instance Cot-1 DNA. Recently, it has become possible to remove repetitive DNA sequences from library probes by means of magnetic purification and affinity PCR. Such a 'repeat depleted library probe' was hybridized to the q-arm of chromosome 15 of human metaphase spreads and interphase cell nuclei without any preannealing by Cot-1 DNA. Apart from this, 'standard' FISH conditions were used. After in situ hybridization, microscope images were obtained comparable to those achieved with the #15q library probe prior to depletion. The images were recorded by a true color CCD camera. By digital image analysis using 'line scan' and 'area scan' procedures, the painting efficiency expressed in terms of relative fluorescence signal intensity was quantitatively evaluated. The painting efficiency using the repeat depleted probe of chromosome 15q was compared to the painting efficiency after standard FISH. The results indicate that both types of probes are compatible to a high FISH efficiency. Using equivalent probe concentrations, no significant differences were found for FISH with standard painting probes and repeat depleted painting probes.
Similar articles
-
Fast-painting of human metaphase spreads using a chromosome-specific, repeat-depleted DNA library probe.Biotechniques. 1998 May;24(5):820-5. doi: 10.2144/98245dt02. Biotechniques. 1998. PMID: 9591132
-
Rapid fluorescence in situ hybridization with repetitive DNA probes: quantification by digital image analysis.Cytometry. 1994 Sep 1;17(1):13-25. doi: 10.1002/cyto.990170103. Cytometry. 1994. PMID: 8001456
-
Removal of repetitive sequences from FISH probes using PCR-assisted affinity chromatography.Hum Genet. 1997 Sep;100(3-4):472-6. doi: 10.1007/s004390050536. Hum Genet. 1997. PMID: 9272175
-
[Selective chromosome painting using in situ hybridization].Sangre (Barc). 1993 Apr;38(2):151-4. Sangre (Barc). 1993. PMID: 8516730 Review. Spanish.
-
[Fluorescence in situ hybridization with DNA probes derived from individual chromosomes and chromosome regions].Mol Biol (Mosk). 2014 Nov-Dec;48(6):881-90. Mol Biol (Mosk). 2014. PMID: 25845229 Review. Russian.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous