Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Jan;32(1):91-9.
doi: 10.1016/s0968-4328(00)00026-3.

The cell in absence of aggregation artifacts

Affiliations
Comparative Study

The cell in absence of aggregation artifacts

J Dubochet et al. Micron. 2001 Jan.

Abstract

Eduard Kellenberger understood that the conventional resin-embedding, he helped to develop (Ryter, A., Kellenberger, E., 1958. L'inclusion au polyester pour l'ultramicrotomie. J. Ultrastruct. Res. , 2, 200-214), was prone to aggregation artifacts (Kellenberger, E., 1987. The response to biological macromolecules and supramolecular structures to the physics of specimen cryo-preparation. In: Steinbrecht, R.A., Zierold, K. (Eds.), Cryo-techniques in Biological Electron Microscopy, Springer, Berlin, pp. 35-63). He was instrumental in developing various methods to overcome this limitation, for instance, by using low temperature-embedding and partially hydrophilic resins (Carlemalm, E., Garavito, R.M., Villiger, W., 1982. Resin development for electron microscopy and an analysis of embedding at low temperature. J. Microstruct., 126, 123-143; Villiger,W., 1993. Low temperature-embedding with Lowicryl resins. In: Robards, A.W., Wilson, A.J. (Eds.), Procedures in electron microscopy, Wiley, Chichester, UK, pp. 16:7.3-16:7.6). In principle, cryo-electron microscopy of vitreous sections is free of any aggregation artifact since the material remains fully hydrated and is free of chemical fixation or staining. The method is technically difficult still, but recent progress has made it amenable to routine practical applications. We compare here electron microscopical aspects of Zea mays meristem cells prepared by: (1) conventional resin-embedding and sectioning; (2) low temperature-embedding and sectioning of freeze substituted samples; and (3) cryo-sections of vitrified samples. The appearance of the extra-cellular space, the cytoplasm and the nucleoplasm are very different in conditions (1) and (3). They appear as compact, irregular and well delineated structures in conventional resin sections, whereas they are more diffuse and homogeneous in the vitreous sections. In the resin sections, the material seems to form a complex matrix, whereas it looks more like a thick soup in the vitreous sample. Low temperature-embedding (condition 2) shows an intermediate appearance. We suggest that regardless of the difference due to staining and different sectioning conditions, the other image differences are the consequence of aggregation artifacts in the resin-embedded specimens.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources