The impact of electron transport on the accuracy of computed dose
- PMID: 10902555
- DOI: 10.1118/1.599004
The impact of electron transport on the accuracy of computed dose
Abstract
The aim of this work was to investigate the accuracy of dose predicted by a Batho power law correction, and two models which account for electron range: A superposition/convolution algorithm and a Monte Carlo algorithm. The results of these models were compared in phantoms with cavities and low-density inhomogeneities. An idealized geometry was considered with inhomogeneities represented by regions of air and lung equivalent material. Measurements were performed with a parallel plate ionization chamber, thin TLDs (thermoluminescent dosimeters) and film. Dose calculations were done with a generalized Batho model, the Pinnacle collapsed cone convolution model (CCC), and the Peregrine Monte Carlo dose calculation algorithm. Absolute central axis and off axis dose data at various depths relative to interfaces of inhomogeneities were compared. Our results confirm that for a Batho correction, dose errors in the calculated depth dose arise from the neglect of electron transport. This effect increases as the field size decreases, as the density of the inhomogeneity decreases, and with the energy of incident photons. The CCC calculations were closer to measurements than the Batho model, but significant discrepancies remain. Monte Carlo results agree with measurements within the measurement and computational uncertainties.
Similar articles
-
Comparison of inhomogeneity correction algorithms in small photon fields.Med Phys. 2005 Mar;32(3):766-76. doi: 10.1118/1.1861154. Med Phys. 2005. PMID: 15839349
-
Comparison of dose calculation algorithms in slab phantoms with cortical bone equivalent heterogeneities.Med Phys. 2007 Aug;34(8):3323-33. doi: 10.1118/1.2750972. Med Phys. 2007. PMID: 17879796
-
Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations.Med Phys. 2002 Jul;29(7):1528-35. doi: 10.1118/1.1487421. Med Phys. 2002. PMID: 12148735
-
A review of electron beam dose calculation algorithms.Australas Phys Eng Sci Med. 1996 Sep;19(3):111-30. Australas Phys Eng Sci Med. 1996. PMID: 8936722 Review.
-
On methods of inhomogeneity corrections for photon transport.Med Phys. 1990 Sep-Oct;17(5):807-14. doi: 10.1118/1.596555. Med Phys. 1990. PMID: 2233566 Review.
Cited by
-
Effect of contrast enhanced CT scans on heterogeneity corrected dose computations in the lung.J Appl Clin Med Phys. 2006 Nov 28;7(4):1-12. doi: 10.1120/jacmp.v7i4.2240. J Appl Clin Med Phys. 2006. PMID: 17533351 Free PMC article.
-
Dose calculation accuracy of lung planning with a commercial IMRT treatment planning system.J Appl Clin Med Phys. 2003 Autumn;4(4):341-51. doi: 10.1120/jacmp.v4i4.2505. J Appl Clin Med Phys. 2003. PMID: 14604424 Free PMC article.
-
Modeling and dosimetric performance evaluation of the RayStation treatment planning system.J Appl Clin Med Phys. 2014 Sep 8;15(5):4787. doi: 10.1120/jacmp.v15i5.4787. J Appl Clin Med Phys. 2014. PMID: 25207563 Free PMC article.
-
Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy.J Appl Clin Med Phys. 2013 Mar 4;14(2):4011. doi: 10.1120/jacmp.v14i2.4011. J Appl Clin Med Phys. 2013. PMID: 23470930 Free PMC article.
-
The effect on tumour control probability of using AXB algorithm in replacement of AAA for SBRT of hepatocellular carcinoma located at lung-liver boundary region.BJR Open. 2021 Nov 24;3(1):20210041. doi: 10.1259/bjro.20210041. eCollection 2021. BJR Open. 2021. PMID: 34877460 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources