Comparative Study
. 2000 Jul;162(1):139-47.
doi: 10.1164/ajrccm.162.1.9906091.

Ventilator-induced overdistension in children: dynamic versus low-flow inflation volume-pressure curves

Affiliations
Comparative Study

Ventilator-induced overdistension in children: dynamic versus low-flow inflation volume-pressure curves

V Nève et al. Am J Respir Crit Care Med. 2000 Jul.

Abstract

We applied to 20 paralyzed ventilated children (0.15 to 14.3 yr, six with acute respiratory distress syndrome [ARDS]) the low-flow inflation (LFI) technique providing quasi-static volume-pressure (V-P) curves and compared the assessment of overdistension (OD) on dynamic and LFI (reference) inspiratory V-P curves. Dynamic curves were obtained at the airway opening during regular constant flow ventilation (Servo 300). Then LFI curves were obtained. Two analyses were performed: First, the nonlinear coefficient c of a second order polynomial equation (SOPE) fitted to dynamic data obtained during constant flow was compared with the c of SOPE fitted to LFI curve (within tidal volume [VT]). Second, the dynamic C20/C (ratio of compliance of the last 20% of the curve (C20) to total compliance [C]) was compared with the determination of the upper inflection point (UIP) on the LFI curve. OD was defined as a negative value of c, a C20/C < 0.80, an UIP included within the VT range for that child during regular ventilation. Using LFI V-P curves as reference, SOPE offered a better detection of OD than dynamic C20/C or the determination of the UIP by graphical means. Indeed the first analysis showed a substantial agreement (kappa 0.75) between dynamic c and LFI c detection of OD whereas the second analysis showed a poor agreement (kappa 0.22) between C20/ C and LFI detection of the UIP. In conclusion, quasi-static V-P curves can easily be obtained in children with the LFI technique. SOPE offers a good detection of OD on dynamic and LFI V-P curves but the C20/C index seems to be an inadequate measure of OD.