Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Jun;9(3):235-40.
doi: 10.1007/s005860000146.

Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients

Affiliations
Clinical Trial

Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients

T Laine et al. Eur Spine J. 2000 Jun.

Abstract

We performed a randomised controlled study to assess the accuracy of computer-assisted pedicle screw insertion versus conventional screw placement under clinical conditions. One hundred patients scheduled for posterior thoracolumbar or lumbosacral pedicle screw instrumentation were randomised into two groups, either for conventional pedicle screw placement or computer-assisted screw application using an optoelectronic navigation system. From the computer-assisted group, nine patients were excluded: one because of an inadequate preoperative computed tomography study, seven because of problems with the specific instruments or the computer system, and one because of an intraoperative anesthesiological complication. Thus, there were 50 patients in the conventional group and 41 in the computer-assisted group, and the number of screws inserted was 277 and 219, respectively. There was no statistical difference between the groups concerning age, gender, diagnosis, type of operation performed, mean operating time, blood loss, or number of screws inserted. The time taken for screw insertion was significantly longer in the computer-assisted group. Postoperatively, screw positions were assessed by an independent radiologist using a sophisticated CT imaging protocol. The pedicle perforation rate was 13.4% in the conventional group and 4.6% in the computer-assisted group (P = 0.006). Pedicle perforations of more than 4 mm were found in 1.4% (4/277) of the screw insertions in the conventional group, and none in the computer-assisted group. Complications not related to pedicle screws were two L5 nerve root lesions, one end plate fracture, one major intraoperative bleeding and one postoperative death in the conventional group, and one deep infection in the computer-assisted group. In conclusion, pedicular screws were inserted more accurately with image-guided computer navigation than with conventional methods.

PubMed Disclaimer

Comment in

  • Reviewer's comment.
    Wittenberg RH. Wittenberg RH. Eur Spine J. 2000 Jun;9(3):241. doi: 10.1007/s005860000147. Eur Spine J. 2000. PMID: 15617201 Free PMC article. No abstract available.

MeSH terms

LinkOut - more resources