Fast maximum entropy approximation in SPECT using the RBI-MAP algorithm
- PMID: 10909924
- DOI: 10.1109/42.848180
Fast maximum entropy approximation in SPECT using the RBI-MAP algorithm
Abstract
In this work, we present a method for approximating constrained maximum entropy (ME) reconstructions of SPECT data with modifications to a block-iterative maximum a posteriori (MAP) algorithm. Maximum likelihood (ML)-based reconstruction algorithms require some form of noise smoothing. Constrained ME provides a more formal method of noise smoothing without requiring the user to select parameters. In the context of SPECT, constrained ME seeks the minimum-information image estimate among those whose projections are a given distance from the noisy measured data, with that distance determined by the magnitude of the Poisson noise. Images that meet the distance criterion are referred to as feasible images. We find that modeling of all principal degrading factors (attenuation, detector response, and scatter) in the reconstruction is critical because feasibility is not meaningful unless the projection model is as accurate as possible. Because the constrained ME solution is the same as a MAP solution for a particular value of the MAP weighting parameter, beta, the constrained ME solution can be found with a MAP algorithm if the correct value of beta is found. We show that the RBI-MAP algorithm, if used with a dynamic scheme for estimating beta, can approximate constrained ME solutions in 20 or fewer iterations. We compare results for various methods of achieving feasible images on a simulation of Tl-201 cardiac SPECT data. Results show that the RBI-MAP ME approximation provides images and quantitative estimates close to those from a slower algorithm that gives the true ME solution. Also, we find that the ME results have higher spatial resolution and greater high-frequency noise content than a feasibility-based stopping rule, feasibility-based low-pass filtering, and a quadratic Gibbs prior with beta selected according to the feasibility criterion. We conclude that fast ME approximation is possible using either RBI-MAP with the dynamic procedure or a feasibility-based stopping rule, and that such reconstructions may be particularly useful in applications where resolution is critical.
Comment in
-
Recent developments in iterative image reconstruction for PET and SPECT.IEEE Trans Med Imaging. 2000 Apr;19(4):257-60. doi: 10.1109/TMI.2000.848177. IEEE Trans Med Imaging. 2000. PMID: 10909921 No abstract available.
Similar articles
-
Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.Phys Med Biol. 1998 Apr;43(4):875-86. doi: 10.1088/0031-9155/43/4/015. Phys Med Biol. 1998. PMID: 9572511
-
A fast and stable maximum a posteriori conjugate gradient reconstruction algorithm.Med Phys. 1995 Aug;22(8):1273-84. doi: 10.1118/1.597614. Med Phys. 1995. PMID: 7476714
-
Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer study.Phys Med Biol. 2015 Sep 7;60(17):6789-809. doi: 10.1088/0031-9155/60/17/6789. Epub 2015 Aug 24. Phys Med Biol. 2015. PMID: 26301337 Free PMC article.
-
Local and Non-local Regularization Techniques in Emission (PET/SPECT) Tomographic Image Reconstruction Methods.J Digit Imaging. 2016 Jun;29(3):394-402. doi: 10.1007/s10278-015-9853-x. J Digit Imaging. 2016. PMID: 26714680 Free PMC article. Review.
-
[Analytical algorithms improving the reconstruction of SPECT image].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2005 Jun;22(3):641-4. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2005. PMID: 16013279 Review. Chinese.
Cited by
-
Image reconstruction for PET/CT scanners: past achievements and future challenges.Imaging Med. 2010 Oct 1;2(5):529-545. doi: 10.2217/iim.10.49. Imaging Med. 2010. PMID: 21339831 Free PMC article.
-
In vivo tumor angiogenesis imaging with site-specific labeled (99m)Tc-HYNIC-VEGF.Eur J Nucl Med Mol Imaging. 2006 Jul;33(7):841-8. doi: 10.1007/s00259-006-0099-1. Eur J Nucl Med Mol Imaging. 2006. PMID: 16699765
-
Detection of focal hypoxic-ischemic injury and neuronal stress in a rodent model of unilateral MCA occlusion/reperfusion using radiolabeled annexin V.Eur J Nucl Med Mol Imaging. 2004 May;31(5):733-9. doi: 10.1007/s00259-004-1473-5. Epub 2004 Feb 21. Eur J Nucl Med Mol Imaging. 2004. PMID: 14985868
-
99mTc-HYNIC-annexin V SPECT imaging of acute stroke and its response to neuroprotective therapy with anti-Fas ligand antibody.Eur J Nucl Med Mol Imaging. 2006 May;33(5):566-74. doi: 10.1007/s00259-005-0046-6. Epub 2006 Feb 14. Eur J Nucl Med Mol Imaging. 2006. PMID: 16477433
-
Experimental investigation of angular stackgram filtering for noise reduction of SPECT projection data: study with linear and nonlinear filters.Int J Biomed Imaging. 2007;2007:38516. doi: 10.1155/2007/38516. Int J Biomed Imaging. 2007. PMID: 18354732 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources