Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2000 Jul;23(7):1127-32.
doi: 10.1111/j.1540-8159.2000.tb00913.x.

Increased variance of P wave duration on the electrocardiogram distinguishes patients with idiopathic paroxysmal atrial fibrillation

Affiliations

Increased variance of P wave duration on the electrocardiogram distinguishes patients with idiopathic paroxysmal atrial fibrillation

G K Andrikopoulos et al. Pacing Clin Electrophysiol. 2000 Jul.

Abstract

We hypothesized that the variance of P wave duration (P variance) in the 12-lead ECG could reflect the spatial dispersion of P wave duration due to inhomogeneous and delayed propagation of sinus impulses in the atria, and moreover could present better reproducibility than maximum P wave duration and P wave dispersion that have already been used for the prediction of idiopathic paroxysmal AF. We also tested a semiautomated PC-based method to improve the accuracy and reproducibility of P wave measurements. A 12-lead ECG was obtained from 60 patients with idiopathic paroxysmal AF and from 50 healthy controls. All ECGs were analyzed manually using magnifying lens and calipers, while 20 randomly selected ones were scanned and analyzed on screen using common commercial software. P maximum, P dispersion, and P variance were all significantly higher in patients with paroxysmal AF than in controls. A P maximum value of 110 ms, a P dispersion value of 40 ms, and a P variance value of 120 ms2 separated patients from controls with a sensitivity of 88%, 83%, and 80%, respectively and a specificity of 75%, 85%, and 74%, respectively. The reproducibility of P variance was higher compared to P dispersion and P maximum. Finally, the PC-based method significantly increased accuracy and reproducibility of P wave measurements. Thus, the variance of P wave duration could be a useful ECG marker for the prediction of paroxysmal idiopathic AF and the use of PC-based methods may enhance the accurate measuring of P wave duration on the ECG.

PubMed Disclaimer

LinkOut - more resources