How many lymph nodes are enough during sentinel lymphadenectomy for primary melanoma?
- PMID: 10923009
- DOI: 10.1067/msy.2000.107418
How many lymph nodes are enough during sentinel lymphadenectomy for primary melanoma?
Abstract
Background: Sentinel lymph node (SLN) biopsy has been shown to reliably identify nodal metastases and the subsequent need for further surgical and adjuvant therapy in patients with cutaneous melanoma. Although SLN identification rates have improved with the addition of radioactive colloid to the blue dye technique, it remains unclear how many lymph nodes should be removed to accurately determine the histologic status of the nodal basin. The objective of this study was to determine the optimal extent of SLN biopsy in these patients.
Methods: The records of 633 consecutive patients with melanoma (765 nodal basins) whose primary treatment included SLN biopsy with the use of a combination of blue dye and technetium Tc 99 labeled sulfur colloid were reviewed. SLN biopsy consisted of the removal of all of the blue-stained nodes and all nodes with radiotracer uptake activity of at least twice background.
Results: SLN biopsy was successful in 765 of 772 basins (99%). A mean of 1.9 SLNs (median, 2 SLNs) per basin were excised. At least 3 SLNs were removed in 176 basins (23%). The overall histologic status of a basin was always established by the first or second SLN harvested (ie, in no patient was the third or subsequent SLN positive when 1 of the first 2 was not). Of the 124 basins containing lymphatic metastases, the SLN that contained the maximal radiotracer uptake (hottest) and/or stained blue was pathologically positive in 118 basins (95%). In only 6 of the 124 positive basins (5%) was the sole evidence of occult nodal metastases identified in an SLN that was neither blue-stained nor the hottest. All but 1 of these SLNs had counts that were at least 66% of the hottest node in the basin.
Conclusions: With a combined modality approach to SLN biopsy, removal of more than 2 SLNs did not provide information that upstaged any patient with primary melanoma. Removal of additional nonblue SLN(s) that contained radioactive counts of at least twice background but lower than two thirds of the SLNs with maximal radiotracer uptake affected patient management in less than 0.2% of all cases. These findings may be helpful in minimizing the extent of surgery and perhaps in reducing the costs and resource use associated with operating room time and pathologic examination.
Similar articles
-
Use of low-dose technetium Tc 99m sulfur colloid to locate sentinel lymph nodes in melanoma of the head and neck: preliminary study.Laryngoscope. 2001 Aug;111(8):1366-72. doi: 10.1097/00005537-200108000-00010. Laryngoscope. 2001. PMID: 11568570
-
Selective sentinel lymph node dissection for melanoma: importance of harvesting nodes with lower radioactive counts without the need for blue dye.Ann Surg Oncol. 2011 Oct;18(10):2919-24. doi: 10.1245/s10434-011-1689-0. Epub 2011 Apr 6. Ann Surg Oncol. 2011. PMID: 21468784
-
Sentinel lymph node biopsy for melanoma: how many radioactive nodes should be removed?Ann Surg Oncol. 2001 Apr;8(3):192-7. doi: 10.1007/s10434-001-0192-4. Ann Surg Oncol. 2001. PMID: 11314933
-
Radioguided sentinel lymph node biopsy in patients with malignant cutaneous melanoma: the nuclear medicine contribution.J Surg Oncol. 2004 Mar;85(3):141-51. doi: 10.1002/jso.20027. J Surg Oncol. 2004. PMID: 14991886 Review.
-
Sentinel lymph node biopsy in patients with primary cutaneous melanoma: study of 455 cases.J Eur Acad Dermatol Venereol. 2000 Jan;14(1):35-45. doi: 10.1046/j.1468-3083.2000.00005.x. J Eur Acad Dermatol Venereol. 2000. PMID: 10877250 Review.
Cited by
-
How many sentinel nodes should be harvested in oral squamous cell carcinoma?Eur Arch Otorhinolaryngol. 2008 Jul;265 Suppl 1(Suppl 1):S19-23. doi: 10.1007/s00405-007-0548-x. Epub 2007 Dec 19. Eur Arch Otorhinolaryngol. 2008. PMID: 18092173 Free PMC article.
-
[Sentinel node biopsy. What are the facts?].Hautarzt. 2005 May;56(5):441-7. doi: 10.1007/s00105-005-0927-4. Hautarzt. 2005. PMID: 15887051 Review. German.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical