Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 May;17(5):300-5.
doi: 10.1046/j.1365-2346.2000.00662.x.

Effects of pneumoperitoneum and reverse Trendelenburg position on cardiopulmonary function in morbidly obese patients receiving laparoscopic gastric banding

Affiliations
Clinical Trial

Effects of pneumoperitoneum and reverse Trendelenburg position on cardiopulmonary function in morbidly obese patients receiving laparoscopic gastric banding

A Casati et al. Eur J Anaesthesiol. 2000 May.

Abstract

We prospectively evaluated the effects of pneumoperitoneum and reverse Trendelenburg position on cardiopulmonary function in 20 ASA physical status II-III morbidly obese patients (body mass index > 35 kg m(-2)) undergoing laparoscopic gastric banding. After general anaesthesia was induced, patients' lungs were ventilated using intermittent positive pressure ventilation (at measurement times, the following parameters were used: tidal volume 12 mL kg(-1) ideal body weight, respiratory rate of 12 bpm, an inspiratory to expiratory time ratio of 1:2). Haemodynamic variables, blood gas parameters, and lung/chest compliance were recorded: in the supine position, after induction of general anaesthesia (T0, baseline) and induction of pneumoperitoneum (T1); after placing the patient in a 25 degree reverse Trendelenburg position (T2); during the surgical time (T3); before deflating the abdomen (T4); after pneumoperitoneum resolution (T5), and before the end of anaesthesia, with the patient supine (T6). The PaO2, PaO2/FiO2 ratio, and lung/chest compliance decreased during the study. After the pneumoperitoneum had been resolved, lung/chest compliance but not oxygenation parameters returned to baseline values. The arterial to end-tidal CO2 tension difference progressively increased from 0.38+/-0.3 kPa (2.85+/-2.25 mmHg) (T0) to 0.63+/-0.3 kPa (4.73+/-2.25 mmHg) (T6). In morbidly obese patients, undergoing laparoscopic gastric banding, a CO2 pneumoperitoneum markedly affected gas exchange and lung/chest compliance, while positioning the patient in a 25 degree reverse Trendelenburg position had no beneficial effects.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources