Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2000 Jul;16(1):178-83.
doi: 10.1034/j.1399-3003.2000.16a29.x.

Scintigraphic comparison of budesonide deposition from two dry powder inhalers

Affiliations
Free article
Clinical Trial

Scintigraphic comparison of budesonide deposition from two dry powder inhalers

S P Newman et al. Eur Respir J. 2000 Jul.
Free article

Abstract

Chlorofluorocarbons (CFCs), used in metered dose inhalers (MDIs), have been identified as being deleterious to the environment leading to a ban on their production. Dry powder inhalers (DPIs) are a widely used alternative to MDIs. One disadvantage of DPIs is that in vivo lung deposition can be influenced by the patient's inspiratory flow rate. The ASTA Medica multi-dose dry powder inhaler (AM-MDPI) has been designed to offer low resistance on inhalation, so that asthmatic patients can achieve inhaled flow rates of approximately 90 L x min(-1). The aim of the study was to evaluate the in vivo deposition of budesonide from the AM-MDPI at different flow rates and to compare this with delivery from a Turbuhaler DPI at a high flow rate. The study was a scintigraphic, randomized, crossover study in which 13 healthy volunteers inhaled a single 200 microg dose of radiolabelled budesonide on four separate occasions with a minimum 44-h washout period between dosings. At the lowest flow rate of 54 L x min(-1), comparable to that for the Turbuhaler (58 L x min(-1)), a similar percentage of the metered dose was delivered to the lung (AM-MDPI median 19.9%; Turbuhaler median 21.4%). At high flow rate (peak inspiratory flow rate 99 L x min(-1)) the AM-MDPI delivered significantly more drug to the lung (median 32.1% of metered dose) than at 65 L x min(-1) or 54 L x min(-1) (median 25.0% and 19.9% of metered dose, respectively), thus demonstrating flow rate dependence. The pattern of regional lung deposition from the AM-MDPI was similar for all three inhalation manoeuvres. It was concluded that the ASTA Medica multi-dose dry powder inhaler achieves at least as much deposition of budesonide in the lungs as a Turbuhaler when used at similar inspiratory flow rates.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources