Management of patients with prosthetic heart valves: potential impact of valve site, clinical characteristics, and comorbidity
- PMID: 10947912
- DOI: 10.1023/a:1018742620401
Management of patients with prosthetic heart valves: potential impact of valve site, clinical characteristics, and comorbidity
Abstract
Nearly four decades have passed since the first mechanical prosthetic aortic valve was placed. Since then several design changes and modifications have been made to improve longevity and hemodynamics and reduce thrombogenicity. Despite these advances thromboembolism remains the major problem for mechanical prosthetic valves. The type and the position of the prosthetic valve and several clinical characteristics such as age greater than 70, atrial fibrillation, depressed left ventricular systolic function, left atrial enlargement, left atrial thrombus and a prior history of systemic embolization influence the risk of thromboembolism and the level of anticoagulation needed to prevent this complication. Through clinical experience guidelines have been developed by the American College of Chest Physicians to determine the optimal level of anticoagulation needed to lower the thromboembolic rate with an acceptable hemorrhagic event rate.
Similar articles
-
Antithrombotic therapy in patients with valvular heart disease and prosthetic heart valves.J Am Coll Cardiol. 1986 Dec;8(6 Suppl B):41B-56B. doi: 10.1016/s0735-1097(86)80006-7. J Am Coll Cardiol. 1986. PMID: 3537070 Review.
-
Mechanical prosthetic heart valves: Quality of anticoagulation and thromboembolic risk. The observational multicenter PLECTRUM study.Int J Cardiol. 2018 Sep 15;267:68-73. doi: 10.1016/j.ijcard.2018.04.042. Int J Cardiol. 2018. PMID: 29957264
-
Failure of guideline-based anticoagulation in a patient with mitral prosthetic valve and recurrent thromboembolism.J Am Soc Echocardiogr. 2008 Mar;21(3):296.e1-3. doi: 10.1016/j.echo.2007.06.015. Epub 2007 Jul 27. J Am Soc Echocardiogr. 2008. PMID: 17681732
-
Incidence of thromboembolic complications in patients with atrial fibrillation or mechanical heart valves with a subtherapeutic international normalized ratio: a prospective multicenter cohort study.Am J Hematol. 2012 Apr;87(4):384-7. doi: 10.1002/ajh.23119. Epub 2012 Feb 24. Am J Hematol. 2012. PMID: 22367852
-
Is it safe and effective to reduce the target anticoagulation range for patients with mechanical prosthetic aortic valves?Interact Cardiovasc Thorac Surg. 2020 Jun 1;30(6):904-909. doi: 10.1093/icvts/ivaa028. Interact Cardiovasc Thorac Surg. 2020. PMID: 32236555 Review.
References