Technical modifications for laparoscopic appendetomy and other pelvic procedures using microinstruments
- PMID: 10961747
Technical modifications for laparoscopic appendetomy and other pelvic procedures using microinstruments
Abstract
Reusable microinstruments are used in a modification of the three-port technique for laparoscopic appendectomy and other pelvic procedures; the method is described herein. Fifty-seven consecutive patients were operated upon using this technique. There was no mortality; there were two minor complications and no conversions to laparotomy. Pain medication needs were minimal in all patients, and the cosmetic results were excellent. The use of microinstruments for pelvic laparoscopic procedures is safe and cost-effective using the technical modifications described.
MeSH terms
LinkOut - more resources