Bispectral analysis technology and equipment
- PMID: 10965721
Bispectral analysis technology and equipment
Abstract
The Bispectral Index or "BIS" is a single number, composed from different EEG features, using multivariate statistical methods. It was designed for monitoring the depth of hypnosis during anaesthesia and sedation. Empirically derived from the EEGs of more than 5,000 anaesthetised patients, the BIS reflects the effect of anaesthetics on the brain. Unlike univariate measures, such as Spectral Edge Frequency or Median Frequency, the Bispectral Index is drug independent and changes with increasing doses of hypnotics in an almost linear way. Though sophisticated technology, the A-2000 BIS monitor and the BIS sensor are easy to use and also allow non-experts to monitor the depth of hypnosis and sedation on a routine basis.
Similar articles
-
Cerebral state monitor, a new small handheld EEG monitor for determining depth of anaesthesia: a clinical comparison with the bispectral index during day-surgery.Eur J Anaesthesiol. 2006 Mar;23(3):208-12. doi: 10.1017/S0265021505002206. Eur J Anaesthesiol. 2006. PMID: 16430792 Clinical Trial.
-
Assessment of recovery in patients undergoing intravenous conscious sedation using bispectral analysis.J Oral Maxillofac Surg. 2001 Jun;59(6):603-11; discussion 611-2. doi: 10.1053/joms.2001.23366. J Oral Maxillofac Surg. 2001. PMID: 11381378 Clinical Trial.
-
Bispectral index does not correlate with observer assessment of alertness and sedation scores during 0.5% bupivacaine epidural anesthesia with nitrous oxide sedation.Anesth Analg. 2006 Aug;103(2):385-9, table of contents. doi: 10.1213/01.ane.0000226090.13170.25. Anesth Analg. 2006. PMID: 16861421
-
Bispectral index and anaesthesia in the elderly.Minerva Anestesiol. 2000 May;66(5):398-402. Minerva Anestesiol. 2000. PMID: 10965724 Review.
-
[Bispectral index: clinical effectiveness and role in reducing anesthetic drug consumption].Minerva Anestesiol. 2000 May;66(5):394-7. Minerva Anestesiol. 2000. PMID: 10965723 Review. Italian.
Cited by
-
Risk of seizures during intraoperative electrocortical stimulation of brain motor areas: a retrospective study on 50 patients.Neurol Sci. 2013 Jan;34(1):63-70. doi: 10.1007/s10072-012-0968-2. Epub 2012 Feb 17. Neurol Sci. 2013. PMID: 22350148
-
Diagnostic Value of the Bispectral Index to Assess Sleep Quality after Elective Surgery in Intensive Care Unit.Indian J Crit Care Med. 2023 Nov;27(11):795-800. doi: 10.5005/jp-journals-10071-24555. Indian J Crit Care Med. 2023. PMID: 37936795 Free PMC article.
-
Comparing Entropy and the Bispectral index with the Ramsay score in sedated ICU patients.J Clin Monit Comput. 2007 Oct;21(5):295-302. doi: 10.1007/s10877-007-9087-7. Epub 2007 Aug 16. J Clin Monit Comput. 2007. PMID: 17701384
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical
Miscellaneous