. 2000;53(2):68-71.
doi: 10.1159/000023516.

Determination of 17-hydroxyprogesterone in plasma by stable isotope dilution/benchtop liquid chromatography-tandem mass spectrometry

Affiliations

Determination of 17-hydroxyprogesterone in plasma by stable isotope dilution/benchtop liquid chromatography-tandem mass spectrometry

S A Wudy et al. Horm Res. 2000.

Abstract

An assay based on stable isotope dilution liquid chromatography-tandem mass spectrometry (ID/LC-MS-MS) was developed for the quantification of 17-hydroxyprogesterone, the most important indicator of 21-hydroxylase deficiency in human plasma. Plasma was extracted using ethyl acetate and Extrelut columns. LC was performed on a reversed-phase C18 column using a water/methanol gradient. A benchtop triple quadrupole mass spectrometer, operating in selected reaction monitoring mode, served as mass detector. The analytical run time was 9 min per sample. The sensitivity was high: 0.06 pmol of 17-hydroxyprogesterone yielded a signal-to-noise ratio of 13. Precision (CV) and accuracy (relative error) derived from the analyses of unspiked and spiked validation samples were 7.4-12.0% and 6.4%, respectively. When analyzing the same samples - median (range), in nanomoles per liter - from neonates and adults independently by ID/LC-MS-MS as well as by ID/gas chromatography (GC)-MS, corresponding results were obtained: neonates (n = 10), ID/LC-MS-MS 3.99 (0.48-16.05), ID/GC-MS 5.39 (1.57-13.02); adults (n = 10), ID/LC-MS-MS 2.66 (1.39-6.15), ID/GC-MS 2.54 (0.51-5.12). The technique permitted reliable detection of classical and nonclassical forms of 21- hydroxylase deficiency. The much simpler sample preparation, the faster analytical run time and the operational ease possible with ID/LC-MS-MS permit a considerable increase of sample testing per day without compromising on analytical sensitivity and specificity. We expect that benchtop tandem mass spectrometry will open new avenues in clinical steroid analysis.

PubMed Disclaimer