Separation of o-, m- and p-phthalic acids by high-field asymmetric waveform ion mobility spectrometry (FAIMS) using mixed carrier gases
- PMID: 10972997
- DOI: 10.1002/1096-9888(200008)35:8<976::AID-JMS25>3.0.CO;2-Q
Separation of o-, m- and p-phthalic acids by high-field asymmetric waveform ion mobility spectrometry (FAIMS) using mixed carrier gases
Abstract
Baseline separation of the three isomers of phthalic acid was achieved in a mixed gas system containing a 95 : 5 mixture of N(2) and CO(2), even though the acids could not be distinguished by high-field asymmetric waveform ion mobility spectrometry (FAIMS) when either pure N(2) or pure CO(2) was used as the carrier gas. Pseudomolecular anions of o-, m- and p-phthalic acids were generated by electrospray ionization and detected, following separation by FAIMS, using a quadrupole mass spectrometer. Addition of small amounts of CO(2) to an N(2) carrier gas also caused the compensation voltages to increase by as much as 12 V, accompanied by 2-7-fold improvements in the measured ion current and dramatic reductions in both adduct ion formation and parent ion fragmentation. Copyright 2000 John Wiley & Sons, Ltd.
Similar articles
-
Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures.Anal Chem. 2004 Dec 15;76(24):7366-74. doi: 10.1021/ac049299k. Anal Chem. 2004. PMID: 15595881
-
Separation of cisplatin and its hydrolysis products using electrospray ionization high-field asymmetric waveform ion mobility spectrometry coupled with ion trap mass spectrometry.Anal Chem. 2003 Nov 1;75(21):5847-53. doi: 10.1021/ac0344182. Anal Chem. 2003. PMID: 14588025
-
Behaviour of tetraalkylammonium ions in high-field asymmetric waveform ion mobility spectrometry.Rapid Commun Mass Spectrom. 2010 May 30;24(10):1392-6. doi: 10.1002/rcm.4539. Rapid Commun Mass Spectrom. 2010. PMID: 20411577
-
Ion mobility-mass spectrometry.J Mass Spectrom. 2008 Jan;43(1):1-22. doi: 10.1002/jms.1383. J Mass Spectrom. 2008. PMID: 18200615 Review.
-
High-field asymmetric waveform ion mobility spectrometry with solvent vapor addition: a potential greener bioanalytical technique.Bioanalysis. 2012 Jun;4(11):1363-75. doi: 10.4155/bio.12.110. Bioanalysis. 2012. PMID: 22720654 Review.
Cited by
-
Improving the efficiency of IMS-IMS by a combing technique.Anal Chem. 2008 Mar 15;80(6):1918-27. doi: 10.1021/ac7018602. Epub 2008 Feb 22. Anal Chem. 2008. PMID: 18290667 Free PMC article.
-
Using gas modifiers to significantly improve sensitivity and selectivity in a cylindrical FAIMS device.J Am Soc Mass Spectrom. 2014 Jul;25(7):1274-84. doi: 10.1007/s13361-014-0878-z. Epub 2014 May 6. J Am Soc Mass Spectrom. 2014. PMID: 24796261
-
Control of ion distortion in field asymmetric waveform ion mobility spectrometry via variation of dispersion field and gas temperature.Anal Chem. 2008 Oct 1;80(19):7508-15. doi: 10.1021/ac800655d. Epub 2008 Aug 27. Anal Chem. 2008. PMID: 18729473 Free PMC article.
-
High-resolution differential ion mobility spectrometry of a protein.Anal Chem. 2013 Jan 2;85(1):10-3. doi: 10.1021/ac3029129. Epub 2012 Dec 17. Anal Chem. 2013. PMID: 23244633 Free PMC article.
-
Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing electrode diameters.J Am Soc Mass Spectrom. 2005 Mar;16(3):349-62. doi: 10.1016/j.jasms.2004.11.013. Epub 2005 Jan 19. J Am Soc Mass Spectrom. 2005. PMID: 15734328
LinkOut - more resources
Full Text Sources
Other Literature Sources