An automated method of sample preparation of biofluids using pierceable caps to eliminate the uncapping of the sample tubes during sample transfer
- PMID: 10989135
- DOI: 10.1016/s0165-022x(00)00117-2
An automated method of sample preparation of biofluids using pierceable caps to eliminate the uncapping of the sample tubes during sample transfer
Abstract
Biological samples are normally collected and stored frozen in capped tubes until analysis. To obtain aliquots of biological samples for analysis, the sample tubes have to be thawed, uncapped, samples removed and then recapped for further storage. In this paper, we report an automated method of sample transfer devised to eliminate the uncapping and recapping process. This sampling method was incorporated into an automated liquid-liquid extraction procedure of plasma samples. Using a robotic system, the plasma samples were transferred directly from pierceable capped tubes into microtubes contained in a 96-position block. The aliquoted samples were extracted with methyl-tert-butyl ether in the same microtubes. The supernatant organic layers were transferred to a 96-well collection plate and evaporated to dryness. The dried extracts were reconstituted and injected from the same plate for analysis by liquid chromatography with tandem mass spectrometry.
Similar articles
-
Increasing the efficiency of pharmacokinetic sample procurement, preparation and analysis by liquid chromatography/tandem mass spectrometry.Rapid Commun Mass Spectrom. 2004;18(10):1066-72. doi: 10.1002/rcm.1447. Rapid Commun Mass Spectrom. 2004. PMID: 15150829
-
Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry.Anal Chem. 2001 Feb 1;73(3):708-14. doi: 10.1021/ac001036c. Anal Chem. 2001. PMID: 11217789
-
High-Throughput Serum 25-Hydroxy Vitamin D Testing with Automated Sample Preparation.Methods Mol Biol. 2016;1378:301-20. doi: 10.1007/978-1-4939-3182-8_32. Methods Mol Biol. 2016. PMID: 26602142
-
Development of restricted-access media supports and their application to the direct analysis of biological fluid samples via high-performance liquid chromatography.Anal Bioanal Chem. 2006 Apr;384(7-8):1462-9. doi: 10.1007/s00216-005-0253-9. Anal Bioanal Chem. 2006. PMID: 16800052 Review.
-
Recent advances in sample preparation techniques to overcome difficulties encountered during quantitative analysis of small molecules from biofluids using LC-MS/MS.Analyst. 2014 May 21;139(10):2265-76. doi: 10.1039/c4an00094c. Analyst. 2014. PMID: 24633191 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous